CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2011-4531 | 1 Siemens | 1 Automation License Manager | 2025-04-11 | 5.0 MEDIUM | N/A |
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command. | |||||
CVE-2012-1800 | 1 Siemens | 4 Scalance S602, Scalance S612, Scalance S613 and 1 more | 2025-04-11 | 6.1 MEDIUM | N/A |
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame. | |||||
CVE-2013-2780 | 1 Siemens | 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more | 2025-04-11 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port). | |||||
CVE-2012-3028 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | 6.8 MEDIUM | N/A |
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service. | |||||
CVE-2012-2441 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2025-04-11 | 8.5 HIGH | N/A |
RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803. | |||||
CVE-2011-4510 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | 4.3 MEDIUM | N/A |
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. | |||||
CVE-2013-0676 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | 4.0 MEDIUM | N/A |
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query. | |||||
CVE-2014-1698 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2025-04-11 | 5.0 MEDIUM | N/A |
Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999. | |||||
CVE-2011-4532 | 1 Siemens | 1 Automation License Manager | 2025-04-11 | 5.0 MEDIUM | N/A |
Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method. | |||||
CVE-2012-3003 | 1 Siemens | 1 Wincc | 2025-04-11 | 5.8 MEDIUM | N/A |
Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request. | |||||
CVE-2013-0677 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | 5.8 MEDIUM | N/A |
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file. | |||||
CVE-2013-0668 | 1 Siemens | 1 Wincc Tia Portal | 2025-04-11 | 4.3 MEDIUM | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in the HMI web application in Siemens WinCC (TIA Portal) 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL. | |||||
CVE-2013-3927 | 1 Siemens | 1 Comos | 2025-04-11 | 4.6 MEDIUM | N/A |
Unspecified vulnerability in the client library in Siemens COMOS 9.2 before 9.2.0.6.10 and 10.0 before 10.0.3.0.4 allows local users to obtain unintended write access to the database by leveraging read access. | |||||
CVE-2013-4778 | 1 Siemens | 2 Enterprise Openscape Branch, Openscape Session Border Controller | 2025-04-11 | 7.8 HIGH | N/A |
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to obtain sensitive server and statistics information via unspecified vectors. | |||||
CVE-2011-4056 | 1 Siemens | 1 Tecnomatix Factorylink | 2025-04-11 | 5.8 MEDIUM | N/A |
An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method. | |||||
CVE-2012-3009 | 1 Siemens | 1 Comos | 2025-04-11 | 8.5 HIGH | N/A |
Siemens COMOS before 9.1 Patch 413, 9.2 before Update 03 Patch 023, and 10.0 before Patch 005 allows remote authenticated users to obtain database administrative access via unspecified method calls. | |||||
CVE-2012-3031 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | 4.3 MEDIUM | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header. | |||||
CVE-2012-2595 | 1 Siemens | 1 Wincc | 2025-04-11 | 4.3 MEDIUM | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 allow remote attackers to inject arbitrary web script or HTML via vectors involving special characters in parameters. | |||||
CVE-2014-1697 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2025-04-11 | 7.5 HIGH | N/A |
The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999. | |||||
CVE-2013-0700 | 1 Siemens | 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more | 2025-04-11 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port). |