CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-7032 | 1 Schneider-electric | 1 Easergy Studio | 2024-11-21 | N/A | 7.8 HIGH |
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker logged in with a user level account to gain higher privileges by providing a harmful serialized object. | |||||
CVE-2023-6407 | 2 Microsoft, Schneider-electric | 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more | 2024-11-21 | N/A | 5.3 MEDIUM |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker. | |||||
CVE-2023-6032 | 1 Schneider-electric | 4 Galaxy Vl, Galaxy Vl Firmware, Galaxy Vs and 1 more | 2024-11-21 | N/A | 5.3 MEDIUM |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause a file system enumeration and file download when an attacker navigates to the Network Management Card via HTTPS. | |||||
CVE-2023-5987 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2024-11-21 | N/A | 6.1 MEDIUM |
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload. | |||||
CVE-2023-5986 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2024-11-21 | N/A | 8.2 HIGH |
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed. | |||||
CVE-2023-5985 | 1 Schneider-electric | 4 Ion8650, Ion8650 Firmware, Ion8800 and 1 more | 2024-11-21 | N/A | 4.8 MEDIUM |
A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system values. | |||||
CVE-2023-5984 | 1 Schneider-electric | 4 Ion8650, Ion8650 Firmware, Ion8800 and 1 more | 2024-11-21 | N/A | 7.2 HIGH |
A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could result in full control over the device. | |||||
CVE-2023-5630 | 1 Schneider-electric | 32 Eb450, Eb450 Firmware, Eb45e and 29 more | 2024-11-21 | N/A | 6.5 MEDIUM |
A CWE-494: Download of Code Without Integrity Check vulnerability exists that could allow a privileged user to install an untrusted firmware. | |||||
CVE-2023-5629 | 1 Schneider-electric | 32 Eb450, Eb450 Firmware, Eb45e and 29 more | 2024-11-21 | N/A | 8.2 HIGH |
A CWE-601:URL Redirection to Untrusted Site (‘Open Redirect’) vulnerability exists that could cause disclosure of information through phishing attempts over HTTP. | |||||
CVE-2023-5402 | 1 Schneider-electric | 1 C-bus Toolkit | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network. | |||||
CVE-2023-5399 | 1 Schneider-electric | 1 Spacelogic C-bus Toolkit | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command. | |||||
CVE-2023-5391 | 1 Schneider-electric | 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports, Ecostruxure Power Scada Operation With Advanced Reports | 2024-11-21 | N/A | 9.8 CRITICAL |
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application. | |||||
CVE-2023-4516 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | N/A | 7.8 HIGH |
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content. | |||||
CVE-2023-3953 | 1 Schneider-electric | 1 Pro-face Gp-pro Ex | 2024-11-21 | N/A | 5.3 MEDIUM |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause memory corruption when an authenticated user opens a tampered log file from GP-Pro EX. | |||||
CVE-2023-37199 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 6.8 MEDIUM |
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually restored. | |||||
CVE-2023-37198 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 6.8 MEDIUM |
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages. | |||||
CVE-2023-37197 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 8.8 HIGH |
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE. | |||||
CVE-2023-37196 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 8.8 HIGH |
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE. | |||||
CVE-2023-2161 | 1 Schneider-electric | 1 Opc Factory Server | 2024-11-21 | N/A | 5.0 MEDIUM |
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. | |||||
CVE-2023-29414 | 1 Schneider-electric | 1 Accutech Manager | 2024-11-21 | N/A | 7.8 HIGH |
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability exists that could cause user privilege escalation if a local user sends specific string input to a local function call. |