CVE-2022-22724 | 1 Schneider-electric | 12 Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware, Modicon M340 Bmxp342000 and 9 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 (HTTP) and 502 (Modbus), when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 (All Versions) | |||||
CVE-2022-22723 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-11-21 | 8.3 HIGH | 8.8 HIGH |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101) | |||||
CVE-2022-22722 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-11-21 | 5.4 MEDIUM | 7.5 HIGH |
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could result in information disclosure. If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to the product they could potentially observe and manipulate traffic associated with product configuration. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101) | |||||
CVE-2022-0715 | 1 Schneider-electric | 66 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 63 more | 2024-11-21 | 6.4 MEDIUM | 9.1 CRITICAL |
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior) | |||||
CVE-2022-0222 | 1 Schneider-electric | 28 Modicon M340 Bmxnoe0100, Modicon M340 Bmxnoe0100 Firmware, Modicon M340 Bmxnoe0110 and 25 more | 2024-11-21 | N/A | 7.5 HIGH |
A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU(BMXNOE* all versions)(BMXNOR* versions prior to v1.7 IR24) | |||||
CVE-2022-0221 | 1 Schneider-electric | 1 Scadapack Workbench | 2024-11-21 | 4.3 MEDIUM | 5.5 MEDIUM |
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a remote system controlled by an attacker. Affected Product: SCADAPack Workbench (6.6.8a and prior) | |||||
CVE-2021-30066 | 2 Belden, Schneider-electric | 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more | 2024-11-21 | 7.2 HIGH | 6.8 MEDIUM |
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400. | |||||
CVE-2021-30065 | 2 Belden, Schneider-electric | 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401. | |||||
CVE-2021-30064 | 2 Belden, Schneider-electric | 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more | 2024-11-21 | 6.8 MEDIUM | 9.8 CRITICAL |
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state). | |||||
CVE-2021-30063 | 2 Belden, Schneider-electric | 22 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 19 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service. | |||||
CVE-2021-30062 | 2 Belden, Schneider-electric | 22 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 19 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer. | |||||
CVE-2021-30061 | 2 Belden, Schneider-electric | 26 Eagle 20 Tofino 943 987-501-tx\/tx, Eagle 20 Tofino 943 987-501-tx\/tx Firmware, Eagle 20 Tofino 943 987-502 -tx\/mm and 23 more | 2024-11-21 | 7.2 HIGH | 6.8 MEDIUM |
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick. | |||||
CVE-2021-22827 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions | |||||
CVE-2021-22826 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions | |||||
CVE-2021-22825 | 1 Schneider-electric | 4 Rack Power Distribution Unit With Network Management Card 2, Rack Power Distribution Unit With Network Management Card 2 Firmware, Rack Power Distribution Unit With Network Management Card 3 and 1 more | 2024-11-21 | 6.0 MEDIUM | 8.0 HIGH |
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier) | |||||
CVE-2021-22824 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Collector | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) | |||||
CVE-2021-22823 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Collector | 2024-11-21 | 5.0 MEDIUM | 9.1 CRITICAL |
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) | |||||
CVE-2021-22822 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
A CWE-79 Improper Neutralization of Input During Web Page Generation (?Cross-site Scripting?) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2) | |||||
CVE-2021-22821 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2024-11-21 | 5.0 MEDIUM | 8.6 HIGH |
A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2) | |||||
CVE-2021-22820 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2) |