CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-13997 | 1 Schneider-electric | 2 Wonderware Indusoft Web Studio, Wonderware Intouch | 2025-04-20 | 10.0 HIGH | 9.8 CRITICAL |
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. | |||||
CVE-2017-9956 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | 7.5 HIGH | 7.3 HIGH |
An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass | |||||
CVE-2017-7970 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2025-04-20 | 3.3 LOW | 6.5 MEDIUM |
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components. | |||||
CVE-2017-7968 | 1 Schneider-electric | 1 Wonderware Indusoft Web Studio | 2025-04-20 | 7.2 HIGH | 7.8 HIGH |
An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges. | |||||
CVE-2017-7689 | 1 Schneider-electric | 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware | 2025-04-20 | 10.0 HIGH | 9.8 CRITICAL |
A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0. | |||||
CVE-2017-7967 | 1 Schneider-electric | 1 Vampset | 2025-04-20 | 2.1 LOW | 5.5 MEDIUM |
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol. | |||||
CVE-2017-7966 | 1 Schneider-electric | 1 Somachine | 2025-04-20 | 6.8 MEDIUM | 8.8 HIGH |
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL. | |||||
CVE-2017-8371 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-04-20 | 4.0 MEDIUM | 6.8 MEDIUM |
Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors. | |||||
CVE-2016-5815 | 1 Schneider-electric | 6 Ion5000, Ion7300, Ion7500 and 3 more | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes. | |||||
CVE-2016-5818 | 1 Schneider-electric | 2 Powerlogic Pm8ecc, Powerlogic Pm8ecc Firmware | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device. | |||||
CVE-2017-9957 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials. | |||||
CVE-2017-14024 | 1 Schneider-electric | 2 Wonderware Indusoft Web Studio, Wonderware Intouch | 2025-04-20 | 10.0 HIGH | 9.8 CRITICAL |
A Stack-based Buffer Overflow issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 Patch 1 and prior versions, and InTouch Machine Edition v8.0 SP2 Patch 1 and prior versions. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution with high privileges. | |||||
CVE-2017-6030 | 1 Schneider-electric | 6 Modicon M221, Modicon M221 Firmware, Modicon M241 and 3 more | 2025-04-20 | 6.4 MEDIUM | 6.5 MEDIUM |
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections. | |||||
CVE-2016-5809 | 1 Schneider-electric | 6 Ion5000, Ion7300, Ion7500 and 3 more | 2025-04-20 | 6.8 MEDIUM | 8.8 HIGH |
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved. | |||||
CVE-2017-7969 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2025-04-20 | 6.8 MEDIUM | 8.8 HIGH |
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack. | |||||
CVE-2017-9959 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | 4.9 MEDIUM | 5.5 MEDIUM |
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system accepts reboot in session from unauthenticated users, supporting a denial of service condition. | |||||
CVE-2017-6017 | 1 Schneider-electric | 30 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 27 more | 2025-04-20 | 7.8 HIGH | 7.5 HIGH |
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover. | |||||
CVE-2017-7965 | 1 Schneider-electric | 1 Somachine Hvac | 2025-04-20 | 4.6 MEDIUM | 7.3 HIGH |
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller. | |||||
CVE-2017-6028 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2025-04-20 | 5.0 MEDIUM | 9.8 CRITICAL |
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application. | |||||
CVE-2017-7973 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database. |