Filtered by vendor Tenda
Subscribe
Total
794 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-18727 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac15 and 7 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. | |||||
CVE-2018-18709 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac15 and 7 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. | |||||
CVE-2018-18708 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac15 and 7 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. | |||||
CVE-2018-18707 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac15 and 7 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. | |||||
CVE-2018-18706 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac15 and 7 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. | |||||
CVE-2018-14559 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac7 and 3 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. | |||||
CVE-2018-14558 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac7 and 3 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. | |||||
CVE-2018-14557 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac7 and 3 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow. | |||||
CVE-2017-16936 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring. | |||||
CVE-2017-16923 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2024-11-21 | 8.3 HIGH | 8.8 HIGH |
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input. | |||||
CVE-2017-14515 | 1 Tenda | 2 W15e, W15e Firmware | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Heap-based Buffer Overflow on Tenda W15E devices before 15.11.0.14 allows remote attackers to cause a denial of service (temporary HTTP outage and forced logout) via unspecified vectors. | |||||
CVE-2017-14514 | 1 Tenda | 2 W15e, W15e Firmware | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Directory Traversal on Tenda W15E devices before 15.11.0.14 allows remote attackers to read unencrypted files via a crafted URL. | |||||
CVE-2015-5995 | 2 Mediabridge, Tenda | 3 Medialink Mwn-wapr300n, Medialink Mwn-wapr300n Firmware, N3 Wireless N150 | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attackers to obtain administrative access via a certain admin substring in an HTTP Cookie header. | |||||
CVE-2014-7281 | 1 Tenda | 2 A32, A32 Firmware | 2024-11-21 | 6.8 MEDIUM | N/A |
Cross-site request forgery (CSRF) vulnerability in Shenzhen Tenda Technology Tenda A32 Router with firmware 5.07.53_CN allows remote attackers to hijack the authentication of administrators for requests that reboot the device via a request to goform/SysToolReboot. | |||||
CVE-2014-5246 | 1 Tenda | 2 A5s, A5s Firmware | 2024-11-21 | 10.0 HIGH | N/A |
The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication and gain administrator access by setting the admin:language cookie to zh-cn. | |||||
CVE-2024-52714 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2024-11-20 | N/A | 9.8 CRITICAL |
Tenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime. | |||||
CVE-2024-11248 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-19 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-11056 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-11061 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-13 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-10750 | 1 Tenda | 2 I22, I22 Firmware | 2024-11-07 | 6.8 MEDIUM | 6.5 MEDIUM |
A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. |