Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 794 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-18727 1 Tenda 10 Ac10, Ac10 Firmware, Ac15 and 7 more 2024-11-21 7.8 HIGH 7.5 HIGH
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18709 1 Tenda 10 Ac10, Ac10 Firmware, Ac15 and 7 more 2024-11-21 7.8 HIGH 7.5 HIGH
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18708 1 Tenda 10 Ac10, Ac10 Firmware, Ac15 and 7 more 2024-11-21 7.8 HIGH 7.5 HIGH
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18707 1 Tenda 10 Ac10, Ac10 Firmware, Ac15 and 7 more 2024-11-21 7.8 HIGH 7.5 HIGH
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18706 1 Tenda 10 Ac10, Ac10 Firmware, Ac15 and 7 more 2024-11-21 7.8 HIGH 7.5 HIGH
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-14559 1 Tenda 6 Ac10, Ac10 Firmware, Ac7 and 3 more 2024-11-21 7.8 HIGH 7.5 HIGH
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.
CVE-2018-14558 1 Tenda 6 Ac10, Ac10 Firmware, Ac7 and 3 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
CVE-2018-14557 1 Tenda 6 Ac10, Ac10 Firmware, Ac7 and 3 more 2024-11-21 7.8 HIGH 7.5 HIGH
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow.
CVE-2017-16936 1 Tenda 6 Ac15, Ac15 Firmware, Ac18 and 3 more 2024-11-21 3.3 LOW 6.5 MEDIUM
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
CVE-2017-16923 1 Tenda 6 Ac15, Ac15 Firmware, Ac18 and 3 more 2024-11-21 8.3 HIGH 8.8 HIGH
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input.
CVE-2017-14515 1 Tenda 2 W15e, W15e Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
Heap-based Buffer Overflow on Tenda W15E devices before 15.11.0.14 allows remote attackers to cause a denial of service (temporary HTTP outage and forced logout) via unspecified vectors.
CVE-2017-14514 1 Tenda 2 W15e, W15e Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
Directory Traversal on Tenda W15E devices before 15.11.0.14 allows remote attackers to read unencrypted files via a crafted URL.
CVE-2015-5995 2 Mediabridge, Tenda 3 Medialink Mwn-wapr300n, Medialink Mwn-wapr300n Firmware, N3 Wireless N150 2024-11-21 10.0 HIGH 9.8 CRITICAL
Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attackers to obtain administrative access via a certain admin substring in an HTTP Cookie header.
CVE-2014-7281 1 Tenda 2 A32, A32 Firmware 2024-11-21 6.8 MEDIUM N/A
Cross-site request forgery (CSRF) vulnerability in Shenzhen Tenda Technology Tenda A32 Router with firmware 5.07.53_CN allows remote attackers to hijack the authentication of administrators for requests that reboot the device via a request to goform/SysToolReboot.
CVE-2014-5246 1 Tenda 2 A5s, A5s Firmware 2024-11-21 10.0 HIGH N/A
The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication and gain administrator access by setting the admin:language cookie to zh-cn.
CVE-2024-52714 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-20 N/A 9.8 CRITICAL
Tenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime.
CVE-2024-11248 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-19 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-11056 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-14 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-11061 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-13 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10750 1 Tenda 2 I22, I22 Firmware 2024-11-07 6.8 MEDIUM 6.5 MEDIUM
A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.