CVE-2024-4064

A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.261790 Permissions Required VDB Entry
https://vuldb.com/?id.261790 Third Party Advisory VDB Entry
https://vuldb.com/?submit.316493 Third Party Advisory VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.261790 Permissions Required VDB Entry
https://vuldb.com/?id.261790 Third Party Advisory VDB Entry
https://vuldb.com/?submit.316493 Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*

History

21 Jan 2025, 19:12

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.261790 - () https://vuldb.com/?ctiid.261790 - Permissions Required, VDB Entry
References () https://vuldb.com/?id.261790 - () https://vuldb.com/?id.261790 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.316493 - () https://vuldb.com/?submit.316493 - Third Party Advisory, VDB Entry
First Time Tenda
Tenda ac8
Tenda ac8 Firmware
CPE cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*
cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*
CWE CWE-787

21 Nov 2024, 09:42

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md -
References () https://vuldb.com/?ctiid.261790 - () https://vuldb.com/?ctiid.261790 -
References () https://vuldb.com/?id.261790 - () https://vuldb.com/?id.261790 -
References () https://vuldb.com/?submit.316493 - () https://vuldb.com/?submit.316493 -

24 Apr 2024, 13:39

Type Values Removed Values Added
Summary
  • (es) Se encontró una vulnerabilidad en Tenda AC8 16.03.34.09. Ha sido declarada crítica. Esta vulnerabilidad afecta a la función R7WebsSecurityHandler del archivo /goform/execCommand. La manipulación del argumento contraseña provoca un desbordamiento de búfer en la región stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. VDB-261790 es el identificador asignado a esta vulnerabilidad. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.

23 Apr 2024, 20:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-04-23 20:15

Updated : 2025-01-21 19:12


NVD link : CVE-2024-4064

Mitre link : CVE-2024-4064

CVE.ORG link : CVE-2024-4064


JSON object : View

Products Affected

tenda

  • ac8_firmware
  • ac8
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write