Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 532 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-0541 1 Tenda 2 W9, W9 Firmware 2024-05-17 9.0 HIGH 9.8 CRITICAL
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. Affected by this vulnerability is the function formAddSysLogRule of the component httpd. The manipulation of the argument sysRulenEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250711. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0540 1 Tenda 2 W9, W9 Firmware 2024-05-17 6.5 MEDIUM 9.8 CRITICAL
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. Affected is the function formOfflineSet of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-250710 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0539 1 Tenda 2 W9, W9 Firmware 2024-05-17 9.0 HIGH 9.8 CRITICAL
A vulnerability was found in Tenda W9 1.0.0.7(4456) and classified as critical. This issue affects the function formQosManage_user of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250709 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0538 1 Tenda 2 W9, W9 Firmware 2024-05-17 9.0 HIGH 9.8 CRITICAL
A vulnerability has been found in Tenda W9 1.0.0.7(4456) and classified as critical. This vulnerability affects the function formQosManage_auto of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250708. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0537 1 Tenda 2 W9, W9 Firmware 2024-05-17 9.0 HIGH 9.8 CRITICAL
A vulnerability, which was classified as critical, was found in Tenda W9 1.0.0.7(4456). This affects the function setWrlBasicInfo of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250707. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0536 1 Tenda 2 W9, W9 Firmware 2024-05-17 9.0 HIGH 9.8 CRITICAL
A vulnerability, which was classified as critical, has been found in Tenda W9 1.0.0.7(4456). Affected by this issue is the function setWrlAccessList of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-250706 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0534 1 Tenda 2 A15, A15 Firmware 2024-05-17 8.3 HIGH 7.2 HIGH
A vulnerability classified as critical has been found in Tenda A15 15.13.07.13. Affected is an unknown function of the file /goform/SetOnlineDevName of the component Web-based Management Interface. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250704. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0533 1 Tenda 2 A15, A15 Firmware 2024-05-17 8.3 HIGH 7.2 HIGH
A vulnerability was found in Tenda A15 15.13.07.13. It has been rated as critical. This issue affects some unknown processing of the file /goform/SetOnlineDevName of the component Web-based Management Interface. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250703. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0532 1 Tenda 2 A15, A15 Firmware 2024-05-17 8.3 HIGH 7.2 HIGH
A vulnerability was found in Tenda A15 15.13.07.13. It has been declared as critical. This vulnerability affects unknown code of the file /goform/WifiExtraSet of the component Web-based Management Interface. The manipulation of the argument wpapsk_crypto2_4g leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-250702 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0531 1 Tenda 2 A15, A15 Firmware 2024-05-17 8.3 HIGH 7.2 HIGH
A vulnerability was found in Tenda A15 15.13.07.13. It has been classified as critical. This affects an unknown part of the file /goform/setBlackRule of the component Web-based Management Interface. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250701 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-4744 1 Tenda 2 Ac8, Ac8 Firmware 2024-05-17 10.0 HIGH 9.8 CRITICAL
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
CVE-2023-2923 1 Tenda 2 Ac6, Ac6 Firmware 2024-05-17 6.5 MEDIUM 9.8 CRITICAL
A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Affected by this vulnerability is the function fromDhcpListClient. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-230077 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-2649 1 Tenda 2 Ac23, Ac23 Firmware 2024-05-17 8.3 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC23 16.03.07.45_cn. It has been declared as critical. This vulnerability affects unknown code of the file /bin/ate of the component Service Port 7329. The manipulation of the argument v2 leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-228778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-0782 1 Tenda 2 Ac23, Ac23 Firmware 2024-05-17 8.3 HIGH 9.8 CRITICAL
A vulnerability was found in Tenda AC23 16.03.07.45 and classified as critical. Affected by this issue is the function formSetSysToolDDNS/formGetSysToolDDNS of the file /bin/httpd. The manipulation leads to out-of-bounds write. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220640.
CVE-2024-30621 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-04-08 N/A 9.8 CRITICAL
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
CVE-2024-30620 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-04-08 N/A 9.8 CRITICAL
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan.
CVE-2024-28553 1 Tenda 1 Ac18 Firmware 2024-03-21 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.
CVE-2024-28535 1 Tenda 1 Ac18 Firmware 2024-03-21 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.
CVE-2024-24543 1 Tenda 2 Ac9, Ac9 Firmware 2024-02-14 N/A 9.8 CRITICAL
Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.
CVE-2022-35201 1 Tenda 2 Ac18, Ac18 Firmware 2024-02-14 N/A 9.8 CRITICAL
Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability.