Filtered by vendor Tenda
Subscribe
Total
794 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-2815 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2814 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2813 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2812 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 6.5 MEDIUM | 6.3 MEDIUM |
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2811 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2810 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2809 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2808 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2807 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2806 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-28553 | 1 Tenda | 1 Ac18 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. | |||||
CVE-2024-28535 | 1 Tenda | 1 Ac18 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. | |||||
CVE-2024-24543 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data. | |||||
CVE-2024-0542 | 1 Tenda | 2 W9, W9 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. Affected by this issue is the function formWifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250712. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0541 | 1 Tenda | 2 W9, W9 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. Affected by this vulnerability is the function formAddSysLogRule of the component httpd. The manipulation of the argument sysRulenEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250711. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0540 | 1 Tenda | 2 W9, W9 Firmware | 2024-11-21 | 6.5 MEDIUM | 6.3 MEDIUM |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. Affected is the function formOfflineSet of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-250710 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0539 | 1 Tenda | 2 W9, W9 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda W9 1.0.0.7(4456) and classified as critical. This issue affects the function formQosManage_user of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250709 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0538 | 1 Tenda | 2 W9, W9 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been found in Tenda W9 1.0.0.7(4456) and classified as critical. This vulnerability affects the function formQosManage_auto of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250708. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0537 | 1 Tenda | 2 W9, W9 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda W9 1.0.0.7(4456). This affects the function setWrlBasicInfo of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250707. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0536 | 1 Tenda | 2 W9, W9 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, has been found in Tenda W9 1.0.0.7(4456). Affected by this issue is the function setWrlAccessList of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-250706 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |