Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 794 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-10661 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-05 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10662 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-05 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10698 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-04 9.0 HIGH 9.8 CRITICAL
A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10697 1 Tenda 2 Ac6, Ac6 Firmware 2024-11-04 6.5 MEDIUM 9.8 CRITICAL
A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac of the component API Endpoint. The manipulation of the argument The leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10434 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-01 9.0 HIGH 9.8 CRITICAL
A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10351 1 Tenda 2 Rx9 Pro, Rx9 Pro Firmware 2024-11-01 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-9793 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-01 6.5 MEDIUM 9.8 CRITICAL
A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-10283 1 Tenda 2 Rx9 Pro, Rx9 Pro Firmware 2024-11-01 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10280 1 Tenda 20 Ac10, Ac10 Firmware, Ac10u and 17 more 2024-11-01 6.8 MEDIUM 7.5 HIGH
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10281 1 Tenda 2 Rx9 Pro, Rx9 Pro Firmware 2024-11-01 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10282 1 Tenda 2 Rx9 Pro, Rx9 Pro Firmware 2024-11-01 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10130 1 Tenda 2 Ac8, Ac8 Firmware 2024-10-28 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-10123 1 Tenda 2 Ac8, Ac8 Firmware 2024-10-28 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-42986 1 Tenda 2 Fh1206, Fh1206 Firmware 2024-10-24 N/A 7.5 HIGH
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42977 1 Tenda 2 Fh1206, Fh1206 Firmware 2024-10-24 N/A 7.5 HIGH
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-8231 1 Tenda 2 O6, O6 Firmware 2024-10-16 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-46045 1 Tenda 2 Ch22, Ch22 Firmware 2024-10-15 N/A 9.8 CRITICAL
Tenda CH22 V1.0.0.6(468) has a stack overflow vulnerability located in the frmL7PlotForm function.
CVE-2023-36103 1 Tenda 2 Ac15, Ac15 Firmware 2024-09-24 N/A 9.8 CRITICAL
Command Injection vulnerability in goform/SetIPTVCfg interface of Tenda AC15 V15.03.05.20 allows remote attackers to run arbitrary commands via crafted POST request.
CVE-2024-46049 1 Tenda 2 O6, O6 Firmware 2024-09-20 N/A 9.8 CRITICAL
Tenda O6 V3.0 firmware V1.0.0.7(2054) contains a stack overflow vulnerability in the formexeCommand function.
CVE-2024-46048 1 Tenda 2 Fh451, Fh451 Firmware 2024-09-20 N/A 9.8 CRITICAL
Tenda FH451 v1.0.0.9 has a command injection vulnerability in the formexeCommand function i