CVE-2023-51097 | 1 Tenda | 2 W9, W9 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetAutoPing. | |||||
CVE-2023-45480 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878. | |||||
CVE-2023-51093 | 1 Tenda | 2 M3, M3 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function fromSetLocalVlanInfo. | |||||
CVE-2023-49434 | 1 Tenda | 2 Ax9, Ax9 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetNetControlList. | |||||
CVE-2023-50984 | 1 Tenda | 2 I29, I29 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the ip parameter in the spdtstConfigAndStart function. | |||||
CVE-2023-38938 | 1 Tenda | 8 F1202, F1202 Firmware, Fh1202 and 5 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im. | |||||
CVE-2023-37714 | 1 Tenda | 8 Ac7, Ac7 Firmware, F1202 and 5 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic. | |||||
CVE-2023-38936 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
CVE-2023-39829 | 1 Tenda | 2 A18, A18 Firmware | 2024-02-05 | N/A | 7.5 HIGH |
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function. | |||||
CVE-2023-39828 | 1 Tenda | 2 A18, A18 Firmware | 2024-02-05 | N/A | 7.5 HIGH |
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function. | |||||
CVE-2023-37716 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | |||||
CVE-2023-38935 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac1206 and 7 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. | |||||
CVE-2023-38931 | 1 Tenda | 16 Ac10, Ac10 Firmware, Ac1206 and 13 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. | |||||
CVE-2023-37715 | 1 Tenda | 4 F1202, F1202 Firmware, Fh1202 and 1 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm. | |||||
CVE-2023-38939 | 1 Tenda | 4 F1202, F1202 Firmware, Fh1202 and 1 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function. | |||||
CVE-2023-38934 | 1 Tenda | 6 F1203, F1203 Firmware, Fh1203 and 3 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function. | |||||
CVE-2023-38933 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | |||||
CVE-2023-37718 | 1 Tenda | 6 4g300, 4g300 Firmware, F1202 and 3 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter. | |||||
CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | |||||
CVE-2023-37723 | 1 Tenda | 10 4g300, 4g300 Firmware, F1202 and 7 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting. |