Filtered by vendor Tenda
Subscribe
Total
794 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-42320 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function. | |||||
CVE-2023-41563 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. | |||||
CVE-2023-41562 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. | |||||
CVE-2023-41561 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. | |||||
CVE-2023-41560 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. | |||||
CVE-2023-41559 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. | |||||
CVE-2023-41558 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg. | |||||
CVE-2023-41557 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac7 and 1 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. | |||||
CVE-2023-41556 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. | |||||
CVE-2023-41555 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet. | |||||
CVE-2023-41554 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. | |||||
CVE-2023-41553 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. | |||||
CVE-2023-41552 | 1 Tenda | 4 Ac7, Ac7 Firmware, Ac9 and 1 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. | |||||
CVE-2023-40915 | 1 Tenda | 2 Ax3, Ax3 Firmware | 2024-11-21 | N/A | 7.5 HIGH |
Tenda AX3 v16.03.12.11 has a stack buffer overflow vulnerability detected at function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter. | |||||
CVE-2023-40904 | 1 Tenda | 2 Ac10v4, Ac10v4 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg. | |||||
CVE-2023-40902 | 1 Tenda | 2 Ac10v4, Ac10v4 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind. | |||||
CVE-2023-40901 | 1 Tenda | 2 Ac10v4, Ac10v4 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg. | |||||
CVE-2023-40900 | 1 Tenda | 2 Ac8v4, Ac8v4 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. | |||||
CVE-2023-40899 | 1 Tenda | 2 Ac8v4, Ac8v4 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg. | |||||
CVE-2023-40898 | 1 Tenda | 2 Ac8v4, Ac8v4 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg. |