Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 609 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-37702 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-30375 1 Tenda 2 Ac15, Ac15 Firmware 2024-02-04 N/A 9.8 CRITICAL
In Tenda AC15 V15.03.05.19, the function "getIfIp" contains a stack-based buffer overflow vulnerability.
CVE-2023-34567 1 Tenda 2 Ac10, Ac10 Firmware 2024-02-04 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-34569 1 Tenda 2 Ac10, Ac10 Firmware 2024-02-04 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
CVE-2023-34571 1 Tenda 2 Ac10, Ac10 Firmware 2024-02-04 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.
CVE-2023-37701 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-33670 1 Tenda 2 Ac8, Ac8 Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function.
CVE-2023-33669 1 Tenda 2 Ac8, Ac8 Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function.
CVE-2023-37704 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-30371 1 Tenda 2 Ac15, Ac15 Firmware 2024-02-04 N/A 9.8 CRITICAL
In Tenda AC15 V15.03.05.19, the function "sub_ED14" contains a stack-based buffer overflow vulnerability.
CVE-2023-30351 1 Tenda 2 Cp3, Cp3 Firmware 2024-02-04 N/A 7.5 HIGH
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for root which is stored using weak encryption. This vulnerability allows attackers to connect to the TELNET service (or UART) by using the exposed credentials.
CVE-2023-30378 1 Tenda 2 Ac15, Ac15 Firmware 2024-02-04 N/A 9.8 CRITICAL
In Tenda AC15 V15.03.05.19, the function "sub_8EE8" contains a stack-based buffer overflow vulnerability.
CVE-2023-30373 1 Tenda 2 Ac15, Ac15 Firmware 2024-02-04 N/A 9.8 CRITICAL
In Tenda AC15 V15.03.05.19, the function "xian_pppoe_user" contains a stack-based buffer overflow vulnerability.
CVE-2023-33673 1 Tenda 2 Ac8, Ac8 Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2023-26805 1 Tenda 2 W20e, W20e Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda W20E v15.11.0.6 (US_W20EV4.0br_v15.11.0.6(1068_1546_841)_CN_TDC) is vulnerable to Buffer Overflow via function formIPMacBindModify.
CVE-2023-30372 1 Tenda 2 Ac15, Ac15 Firmware 2024-02-04 N/A 9.8 CRITICAL
In Tenda AC15 V15.03.05.19, The function "xkjs_ver32" contains a stack-based buffer overflow vulnerability.
CVE-2023-34566 1 Tenda 2 Ac10, Ac10 Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
CVE-2023-37712 1 Tenda 6 Ac1206, Ac1206 Firmware, F1202 and 3 more 2024-02-04 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
CVE-2023-37700 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-02-04 N/A 9.8 CRITICAL
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-37711 1 Tenda 4 Ac10, Ac10 Firmware, Ac1206 and 1 more 2024-02-04 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.