Total
56 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-42345 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-10 | N/A | 4.3 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP2). The affected application does not properly handle user session establishment and invalidation. This could allow a remote attacker to circumvent the additional multi factor authentication for user session establishment. | |||||
CVE-2024-39874 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 7.5 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks. | |||||
CVE-2024-39873 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 7.5 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks. | |||||
CVE-2024-39872 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 9.9 CRITICAL |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the 'Manage firmware updates' role to escalate their privileges on the underlying OS level. | |||||
CVE-2024-39870 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 7.8 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate privileges. | |||||
CVE-2024-39869 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 6.5 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually. | |||||
CVE-2024-39868 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 7.3 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges. | |||||
CVE-2024-39867 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 7.3 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges. | |||||
CVE-2024-39866 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 8.8 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges. | |||||
CVE-2024-39865 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-09 | N/A | 8.8 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution. | |||||
CVE-2024-39570 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-06 | N/A | 8.8 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges. | |||||
CVE-2024-39571 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-06 | N/A | 8.8 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges. | |||||
CVE-2024-39871 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-09-06 | N/A | 5.4 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to. | |||||
CVE-2024-39876 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-08-07 | N/A | 4.0 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device. | |||||
CVE-2024-39875 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-08-07 | N/A | 4.3 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows authenticated, low privilege users with the 'Manage own remote connections' permission to retrieve details about other users and group memberships. | |||||
CVE-2021-40438 | 9 Apache, Broadcom, Debian and 6 more | 18 Http Server, Brocade Fabric Operating System Firmware, Debian Linux and 15 more | 2024-07-24 | 6.8 MEDIUM | 9.0 CRITICAL |
A crafted request uri-path can cause mod_proxy to forward the request to an origin server choosen by the remote user. This issue affects Apache HTTP Server 2.4.48 and earlier. | |||||
CVE-2022-32262 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-07-09 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution. | |||||
CVE-2022-32261 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-07-09 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a misconfiguration in the APT update. This could allow an attacker to add insecure packages to the application. | |||||
CVE-2022-32260 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-07-09 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios. | |||||
CVE-2022-32259 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-07-09 | 6.4 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The system images for installation or update of the affected application contain unit test scripts with sensitive information. An attacker could gain information about testing architecture and also tamper with test configuration. |