Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1889 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-41546 1 Siemens 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more 2024-11-21 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service.
CVE-2021-41545 1 Siemens 8 Desigo Dxr2, Desigo Dxr2 Firmware, Desigo Pxc3 and 5 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a “out of work” state and could result in the controller going into a “factory reset” state.
CVE-2021-41544 1 Siemens 1 Software Center 2024-11-21 N/A 7.8 HIGH
A vulnerability has been identified in Siemens Software Center (All versions < V3.0). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
CVE-2021-41543 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The handling of log files in the web application of affected devices contains an information disclosure vulnerability which could allow logged in users to access sensitive files.
CVE-2021-41542 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The User Management page of affected devices is vulnerable to cross-site scripting (XSS). The vulnerability allows an attacker to send malicious JavaScript code which could result in hijacking of the user's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser action.
CVE-2021-41541 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The Group Management page of affected devices is vulnerable to cross-site scripting (XSS). The vulnerability allows an attacker to send malicious JavaScript code which could result in hijacking of the user's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser action.
CVE-2021-41540 1 Siemens 1 Solid Edge 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13776).
CVE-2021-41539 1 Siemens 1 Solid Edge 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13773).
CVE-2021-41538 1 Siemens 13 Nx 1957, Nx 1957 Firmware, Nx 1961 and 10 more 2024-11-21 4.3 MEDIUM 3.3 LOW
A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files. An attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770).
CVE-2021-41537 1 Siemens 1 Solid Edge 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13789).
CVE-2021-41536 1 Siemens 1 Solid Edge 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).
CVE-2021-41535 1 Siemens 13 Nx 1957, Nx 1957 Firmware, Nx 1961 and 10 more 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).
CVE-2021-41534 1 Siemens 5 Nx 1984, Nx 1984 Firmware, Nx 1988 and 2 more 2024-11-21 4.3 MEDIUM 3.3 LOW
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13703).
CVE-2021-41533 1 Siemens 5 Nx 1984, Nx 1984 Firmware, Nx 1988 and 2 more 2024-11-21 4.3 MEDIUM 3.3 LOW
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565).
CVE-2021-41057 3 Microsoft, Siemens, Wibu 11 Windows, Pss Cape, Pss E and 8 more 2024-11-21 3.6 LOW 7.1 HIGH
In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.
CVE-2021-40368 1 Siemens 8 Simatic S7-400 Pn\/dp V7, Simatic S7-400 Pn\/dp V7 Firmware, Simatic S7-400h V6 and 5 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions < V10.1), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions < V8.2.3). Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations.
CVE-2021-40366 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 5.8 MEDIUM 7.4 HIGH
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.
CVE-2021-40365 1 Siemens 192 Simatic Et 200 Sp Open Controller Cpu 1515sp Pc, Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware, Simatic S7-1200 Cpu 1211c and 189 more 2024-11-21 N/A 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller CPU 1504D TF, SIMATIC Drive Controller CPU 1507D TF, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU 1510SP F-1 PN, SIMATIC S7-1500 CPU 1510SP-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511T-1 PN, SIMATIC S7-1500 CPU 1511TF-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512SP F-1 PN, SIMATIC S7-1500 CPU 1512SP-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513R-1 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515R-2 PN, SIMATIC S7-1500 CPU 1515T-2 PN, SIMATIC S7-1500 CPU 1515TF-2 PN, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516T-3 PN/DP, SIMATIC S7-1500 CPU 1516TF-3 PN/DP, SIMATIC S7-1500 CPU 1517-3 PN/DP, SIMATIC S7-1500 CPU 1517F-3 PN/DP, SIMATIC S7-1500 CPU 1517H-3 PN, SIMATIC S7-1500 CPU 1517T-3 PN/DP, SIMATIC S7-1500 CPU 1517TF-3 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518F-4 PN/DP, SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518HF-4 PN, SIMATIC S7-1500 CPU 1518T-4 PN/DP, SIMATIC S7-1500 CPU 1518TF-4 PN/DP, SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK, SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK, SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN, SIMATIC S7-1500 Software Controller, SIMATIC S7-PLCSIM Advanced, SIPLUS ET 200SP CPU 1510SP F-1 PN, SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN RAIL, SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL, SIPLUS S7-1500 CPU 1515R-2 PN, SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1517H-3 PN, SIPLUS S7-1500 CPU 1518-4 PN/DP, SIPLUS S7-1500 CPU 1518-4 PN/DP MFP, SIPLUS S7-1500 CPU 1518F-4 PN/DP, SIPLUS S7-1500 CPU 1518HF-4 PN, SIPLUS TIM 1531 IRC, TIM 1531 IRC. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device
CVE-2021-40364 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
CVE-2021-40363 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 2.1 LOW 7.8 HIGH
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.