Vulnerabilities (CVE)

Filtered by vendor Mitsubishielectric Subscribe
Total 154 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-29832 1 Mitsubishielectric 1 Gx Works3 2024-02-04 N/A 6.5 MEDIUM
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.
CVE-2022-29826 1 Mitsubishielectric 1 Gx Works3 2024-02-04 N/A 7.5 HIGH
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
CVE-2022-29825 1 Mitsubishielectric 1 Gx Works3 2024-02-04 N/A 7.5 HIGH
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
CVE-2022-29831 1 Mitsubishielectric 1 Gx Works3 2024-02-04 N/A 7.5 HIGH
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
CVE-2022-33323 1 Mitsubishielectric 102 Rh-12fh55, Rh-12fh55 Firmware, Rh-12fh70 and 99 more 2024-02-04 N/A 7.5 HIGH
Active Debug Code vulnerability in robot controller of Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series allows a remote unauthenticated attacker to gain unauthorized access by authentication bypass through an unauthorized telnet login. As for the affected model names, controller types and firmware versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
CVE-2022-29829 1 Mitsubishielectric 1 Gx Works3 2024-02-04 N/A 7.5 HIGH
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
CVE-2022-29830 1 Mitsubishielectric 1 Gx Works3 2024-02-04 N/A 9.1 CRITICAL
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
CVE-2022-33315 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2024-02-04 N/A 7.8 HIGH
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
CVE-2022-33318 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2024-02-04 N/A 9.8 CRITICAL
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server.
CVE-2022-33319 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2024-02-04 N/A 9.1 CRITICAL
Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server.
CVE-2022-33317 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2024-02-04 N/A 7.8 HIGH
Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.
CVE-2022-33321 2 Mitshubishielectric, Mitsubishielectric 356 Mac-507if-e, Mac-507if-e Firmware, Mac-587if-e and 353 more 2024-02-04 N/A 9.8 CRITICAL
Cleartext Transmission of Sensitive Information vulnerability due to the use of Basic Authentication for HTTP connections in Mitsubishi Electric consumer electronics products (PHOTOVOLTAIC COLOR MONITOR ECO-GUIDE, HEMS adapter, Wi-Fi Interface, Air Conditioning, Induction hob, Mitsubishi Electric HEMS Energy Measurement Unit, Refrigerator, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator, Smart Switch, Ventilating Fan, Range hood fan, Energy Measurement Unit and Air Purifier) allows a remote unauthenticated attacker to disclose information in the products or cause a denial of service (DoS) condition as a result by sniffing credential information (username and password). The wide range of models/versions of Mitsubishi Electric consumer electronics products are affected by this vulnerability. As for the affected product models/versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
CVE-2022-33322 1 Mitsubishielectric 238 Ma-ew85s-e, Ma-ew85s-e Firmware, Ma-ew85s-uk and 235 more 2024-02-04 N/A 6.1 MEDIUM
Cross-site scripting vulnerability in Mitsubishi Electric consumer electronics products (Air Conditioning, Wi-Fi Interface, Refrigerator, HEMS adapter, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator, Smart Switch and Air Purifier) allows a remote unauthenticated attacker to execute an malicious script on a user's browser to disclose information, etc. The wide range of models/versions of Mitsubishi Electric consumer electronics products are affected by this vulnerability. As for the affected product models/versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
CVE-2022-33316 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2024-02-04 N/A 7.8 HIGH
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
CVE-2022-33320 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2024-02-04 N/A 7.8 HIGH
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.
CVE-2022-25159 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-02-04 6.8 MEDIUM 8.1 HIGH
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to login to the product by replay attack.
CVE-2022-25157 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-02-04 6.4 MEDIUM 9.1 CRITICAL
Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GF11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GP21(S)-SX all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to disclose or tamper with the information in the product by using an eavesdropped password hash.
CVE-2022-25156 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-02-04 6.8 MEDIUM 8.1 HIGH
Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by using a password reversed from a previously eavesdropped password hash.
CVE-2022-25161 2 Mitsubhishielectric, Mitsubishielectric 194 Melsec Iq-fx5u-32mr\/ds, Melsec Iq-fx5u-32mr\/ds Firmware, Melsec Iq-fx5u-32mr\/dss and 191 more 2024-02-04 7.8 HIGH 8.6 HIGH
Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/z(x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later and versions prior to 1.270, Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/z(x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179**** and prior and versions prior to 1.073, MELSEC iQ-F series FX5UC-xMy/z(x=32,64,96, y=T,R, z=D,DSS) with serial number 17X**** or later and versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-xMy/z(x=32,64,96, y=T,R, z=D,DSS) with serial number 179**** and prior and versions prior to 1.073, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MT/DS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MT/DSS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MR/DS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UJ-xMy/z(x=24,40,60, y=T,R, z=ES,ESS) versions prior to 1.030, Mitsubishi Electric MELSEC iQ-F series FX5UJ-xMy/ES-A(x=24,40,60, y=T,R) versions prior to 1.031 and Mitsubishi Electric MELSEC iQ-F series FX5S-xMy/z(x=30,40,60,80, y=T,R, z=ES,ESS) version 1.000 allows a remote unauthenticated attacker to cause a DoS condition for the product's program execution or communication by sending specially crafted packets. System reset of the product is required for recovery.
CVE-2022-25155 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-02-04 6.8 MEDIUM 8.1 HIGH
Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GN11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GN11-EIP all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by replaying an eavesdropped password hash.