CVE-2019-14927 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2024-09-10 | 5.0 MEDIUM | 7.5 HIGH |
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data). | |||||
CVE-2019-14926 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2024-09-10 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the vendor web sites. | |||||
CVE-2019-14925 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2024-09-10 | 4.0 MEDIUM | 6.5 MEDIUM |
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment. | |||||
CVE-2018-16061 | 1 Mitsubishielectric | 2 Smartrtu, Smartrtu Firmware | 2024-09-10 | 4.3 MEDIUM | 6.1 MEDIUM |
Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php. | |||||
CVE-2018-16060 | 1 Mitsubishielectric | 2 Smartrtu, Smartrtu Firmware | 2024-09-10 | 5.0 MEDIUM | 7.5 HIGH |
Mitsubishi Electric Europe B.V. SmartRTU devices allow remote attackers to obtain sensitive information (directory listing and source code) via a direct request to the /web URI. | |||||
CVE-2024-25088 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-08-01 | N/A | 7.8 HIGH |
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code. | |||||
CVE-2024-25086 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-07-08 | N/A | 7.8 HIGH |
Improper privilege management in Jungo WinDriver before 12.2.0 allows local attackers to escalate privileges and execute arbitrary code. | |||||
CVE-2024-22104 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-07-08 | N/A | 5.5 MEDIUM |
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS). | |||||
CVE-2024-26314 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-07-05 | N/A | 7.8 HIGH |
Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code. | |||||
CVE-2024-22106 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-07-05 | N/A | 7.8 HIGH |
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges, execute arbitrary code, or cause a Denial of Service (DoS). | |||||
CVE-2024-22103 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-07-05 | N/A | 5.5 MEDIUM |
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS). | |||||
CVE-2024-22102 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-07-05 | N/A | 5.5 MEDIUM |
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error. | |||||
CVE-2023-51778 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-07-05 | N/A | 5.5 MEDIUM |
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS). | |||||
CVE-2023-51776 | 2 Jungo, Mitsubishielectric | 43 Windriver, Cpu Module Logging Configuration Tool, Cw Configurator and 40 more | 2024-07-05 | N/A | 7.8 HIGH |
Improper privilege management in Jungo WinDriver before 12.1.0 allows local attackers to escalate privileges and execute arbitrary code. | |||||
CVE-2023-4088 | 1 Mitsubishielectric | 1 Gx Works3 | 2024-07-04 | N/A | 7.8 HIGH |
Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder. | |||||
CVE-2021-20597 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-05-24 | 6.4 MEDIUM | 9.1 CRITICAL |
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password. | |||||
CVE-2021-20594 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-05-24 | 5.0 MEDIUM | 7.5 HIGH |
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via brute-force attack on user names. | |||||
CVE-2021-20599 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-04-18 | 5.0 MEDIUM | 7.5 HIGH |
Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions "26" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password. | |||||
CVE-2023-4625 | 1 Mitsubishielectric | 126 Fx5s-30mr\/es, Fx5s-30mr\/es Firmware, Fx5s-30mt\/es and 123 more | 2024-02-15 | N/A | 5.3 MEDIUM |
Improper Restriction of Excessive Authentication Attempts vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F/iQ-R Series CPU modules Web server function allows a remote unauthenticated attacker to prevent legitimate users from logging into the Web server function for a certain period after the attacker has attempted to log in illegally by continuously attempting unauthorized login to the Web server function. The impact of this vulnerability will persist while the attacker continues to attempt unauthorized login. | |||||
CVE-2023-6374 | 1 Mitsubishielectric | 2 Melsec Ws0-geth00200, Melsec Ws0-geth00200 Firmware | 2024-02-06 | N/A | 7.5 HIGH |
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules. |