Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 719 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-30237 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2024-11-21 5.0 MEDIUM 8.2 HIGH
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30236 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2024-11-21 6.4 MEDIUM 8.2 HIGH
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30235 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2024-11-21 5.0 MEDIUM 8.6 HIGH
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30234 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2024-11-21 10.0 HIGH 9.4 CRITICAL
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30233 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2024-11-21 4.3 MEDIUM 6.5 MEDIUM
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30232 1 Schneider-electric 2 Powerlogic Ion Setup, Powerlogic Ion Setup Firmware 2024-11-21 6.5 MEDIUM 8.0 HIGH
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-26507 2 Att, Schneider-electric 9 Xmill, Ecostruxure Control Expert, Ecostruxure Process Expert and 6 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
** UNSUPPORTED WHEN ASSIGNED ** A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2022-24323 1 Schneider-electric 2 Ecostruxure Control Expert, Ecostruxure Process Expert 2024-11-21 4.3 MEDIUM 5.3 MEDIUM
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)
CVE-2022-24322 1 Schneider-electric 1 Ecostruxure Control Expert 2024-11-21 4.3 MEDIUM 5.3 MEDIUM
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)
CVE-2022-24321 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-24320 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-24319 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-24318 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 5.0 MEDIUM 7.5 HIGH
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-24317 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 5.0 MEDIUM 7.5 HIGH
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24316 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 5.0 MEDIUM 7.5 HIGH
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24315 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 5.0 MEDIUM 7.5 HIGH
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24314 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 5.0 MEDIUM 7.5 HIGH
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24313 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 7.5 HIGH 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24312 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 7.5 HIGH 9.8 CRITICAL
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24311 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 7.5 HIGH 9.8 CRITICAL
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)