Vulnerabilities (CVE)

Filtered by CWE-287
Total 3303 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-7226 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-02-04 5.8 MEDIUM 8.8 HIGH
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
CVE-2019-5223 1 Huawei 1 Pcmanager 2024-02-04 6.8 MEDIUM 7.8 HIGH
PCManager 9.1.3.1 has an improper authentication vulnerability. The certain driver interface of the software does not perform a validation of user-mode data properly, successful exploit could result in malicious code execution.
CVE-2019-10964 1 Medtronic 38 Minimed 508, Minimed 508 Firmware, Minimed Paradigm 511 and 35 more 2024-02-04 5.8 MEDIUM 8.8 HIGH
In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump – All versions, MiniMed Paradigm 511 pump – All versions, MiniMed Paradigm 512/712 pumps – All versions, MiniMed Paradigm 712E pump–All versions, MiniMed Paradigm 515/715 pumps–All versions, MiniMed Paradigm 522/722 pumps – All versions,MiniMed Paradigm 522K/722K pumps – All versions, MiniMed Paradigm 523/723 pumps – Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps – Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps – Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only – Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
CVE-2019-1937 1 Cisco 3 Integrated Management Controller Supervisor, Ucs Director, Ucs Director Express For Big Data 2024-02-04 10.0 HIGH 9.8 CRITICAL
A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) Supervisor, Cisco UCS Director, and Cisco UCS Director Express for Big Data could allow an unauthenticated, remote attacker to acquire a valid session token with administrator privileges, bypassing user authentication. The vulnerability is due to insufficient request header validation during the authentication process. An attacker could exploit this vulnerability by sending a series of malicious requests to an affected device. An exploit could allow the attacker to use the acquired session token to gain full administrator access to the affected device.
CVE-2018-11426 1 Moxa 4 Oncell G3150-hspa, Oncell G3150-hspa-t, Oncell G3150-hspa-t Firmware and 1 more 2024-02-04 7.5 HIGH 9.8 CRITICAL
A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change.
CVE-2019-5679 2 Google, Nvidia 2 Android, Shield Experience 2024-02-04 7.2 HIGH 7.8 HIGH
NVIDIA Shield TV Experience prior to v8.0, NVIDIA Tegra bootloader contains a vulnerability in nvtboot where the Trusted OS image is improperly authenticated, which may lead to code execution, denial of service, escalation of privileges, and information disclosure, code execution, denial of service, or escalation of privileges
CVE-2015-7882 1 Mongodb 1 Mongodb 2024-02-04 6.8 MEDIUM 8.1 HIGH
Improper handling of LDAP authentication in MongoDB Server versions 3.0.0 to 3.0.6 allows an unauthenticated client to gain unauthorized access.
CVE-2019-3927 1 Crestron 4 Am-100, Am-100 Firmware, Am-101 and 1 more 2024-02-04 5.0 MEDIUM 9.8 CRITICAL
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user's password and gain access to restricted areas on the HTTP interface.
CVE-2019-1938 1 Cisco 2 Ucs Director, Ucs Director Express For Big Data 2024-02-04 10.0 HIGH 9.8 CRITICAL
A vulnerability in the web-based management interface of Cisco UCS Director and Cisco UCS Director Express for Big Data could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrator privileges on an affected system. The vulnerability is due to improper authentication request handling. An attacker could exploit this vulnerability by sending crafted HTTP requests to an affected device. A successful exploit could allow an unprivileged attacker to access and execute arbitrary actions through certain APIs.
CVE-2019-5298 1 Huawei 2 Ap4050dn-e, Ap4050dn-e Firmware 2024-02-04 4.6 MEDIUM 6.8 MEDIUM
There is an improper authentication vulnerability in some Huawei AP products before version V200R009C00SPC800. Due to the improper implementation of authentication for the serial port, an attacker could exploit this vulnerability by connecting to the affected products and running a series of commands.
CVE-2019-9629 1 Sonatype 1 Nexus Repository Manager 2024-02-04 7.5 HIGH 9.8 CRITICAL
Sonatype Nexus Repository Manager before 3.17.0 establishes a default administrator user with weak defaults (fixed credentials).
CVE-2019-11234 4 Canonical, Fedoraproject, Freeradius and 1 more 4 Ubuntu Linux, Fedora, Freeradius and 1 more 2024-02-04 7.5 HIGH 9.8 CRITICAL
FreeRADIUS before 3.0.19 does not prevent use of reflection for authentication spoofing, aka a "Dragonblood" issue, a similar issue to CVE-2019-9497.
CVE-2018-7076 1 Hp 1 Intelligent Management Center 2024-02-04 10.0 HIGH 9.8 CRITICAL
A remote code execution vulnerability was identified in HPE Intelligent Management Center (iMC) prior to iMC PLAT 7.3 E0605P04.
CVE-2018-17923 1 Sagaradio 2 Saga1-l8b, Saga1-l8b Firmware 2024-02-04 6.9 MEDIUM 6.9 MEDIUM
SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that an attacker with physical access to the product may able to reprogram it.
CVE-2019-6521 1 Advantech 1 Webaccess\/scada 2024-02-04 7.5 HIGH 8.6 HIGH
WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information.
CVE-2018-17928 1 Abb 2 Cms-770, Cms-770 Firmware 2024-02-04 3.3 LOW 6.5 MEDIUM
The product CMS-770 (Software Versions 1.7.1 and prior)is vulnerable that an attacker can read sensitive configuration files by bypassing the user authentication mechanism.
CVE-2018-6011 1 Rainmachine 2 Mini-8, Mini-8 Firmware 2024-02-04 6.8 MEDIUM 8.1 HIGH
The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine Mini-8 (2nd generation) uses the administrator's password hash to generate a 6-digit temporary passcode that can be used for remote and local access, aka a "Use of Password Hash Instead of Password for Authentication" issue. This is exploitable by an attacker who discovers a hash value in the rainmachine-settings.sqlite file.
CVE-2018-13789 1 Descor 1 Infocad Fm 2024-02-04 5.0 MEDIUM 7.5 HIGH
An issue was discovered in Descor Infocad FM before 3.1.0.0. An unauthenticated web service allows the retrieval of files on the web server and on reachable SMB servers.
CVE-2019-1666 1 Cisco 1 Hyperflex Hx Data Platform 2024-02-04 5.0 MEDIUM 5.3 MEDIUM
A vulnerability in the Graphite service of Cisco HyperFlex software could allow an unauthenticated, remote attacker to retrieve data from the Graphite service. The vulnerability is due to insufficient authentication controls. An attacker could exploit this vulnerability by sending crafted requests to the Graphite service. A successful exploit could allow the attacker to retrieve any statistics from the Graphite service. Versions prior to 3.5(2a) are affected.
CVE-2018-1000875 1 Berkeley 1 Berkeley Open Infrastructure For Network Computing 2024-02-04 7.5 HIGH 9.8 CRITICAL
Berkeley Open Infrastructure for Network Computing BOINC Server and Website Code version 0.9-1.0.2 contains a CWE-302: Authentication Bypass by Assumed-Immutable Data vulnerability in Website Terms of Service Acceptance Page that can result in Access to any user account. This attack appear to be exploitable via Specially crafted URL. This vulnerability appears to have been fixed in 1.0.3.