Filtered by vendor Ui
Subscribe
Total
77 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-5426 | 1 Ui | 1 Edgeswitch X | 2024-11-21 | 5.8 MEDIUM | 4.8 MEDIUM |
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, an unauthenticated user can use the "local port forwarding" and "dynamic port forwarding" (SOCKS proxy) functionalities. Remote attackers without credentials can exploit this bug to access local services or forward traffic through the device if SSH is enabled in the system settings. | |||||
CVE-2019-5425 | 1 Ui | 1 Edgeswitch X | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, an authenticated user can execute arbitrary shell commands over the SSH interface bypassing the CLI interface, which allow them to escalate privileges to root. | |||||
CVE-2019-5424 | 1 Ui | 1 Edgeswitch X | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user. | |||||
CVE-2018-12590 | 1 Ui | 2 Edgeswitch, Edgeswitch Firmware | 2024-11-21 | 9.0 HIGH | 7.2 HIGH |
Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code. | |||||
CVE-2017-0938 | 1 Ui | 4 Airmax Ac, Airos, Edgemax and 1 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Denial of Service attack in airMAX < 8.3.2 , airMAX < 6.0.7 and EdgeMAX < 1.9.7 allow attackers to use the Discovery Protocol in amplification attacks. | |||||
CVE-2017-0935 | 1 Ui | 1 Edgeos | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system. | |||||
CVE-2017-0912 | 1 Ui | 1 Ucrm | 2024-11-21 | 3.5 LOW | 5.4 MEDIUM |
Ubiquiti UCRM versions 2.5.0 to 2.7.7 are vulnerable to Stored Cross-site Scripting. Due to the lack sanitization, it is possible to inject arbitrary HTML code by manipulating the uploaded filename. Successful exploitation requires valid credentials to an account with "Edit" access to "Scheduling". | |||||
CVE-2016-6914 | 2 Microsoft, Ui | 2 Windows, Unifi Video | 2024-11-21 | 7.2 HIGH | 7.8 HIGH |
Ubiquiti UniFi Video before 3.8.0 for Windows uses weak permissions for the installation directory, which allows local users to gain SYSTEM privileges via a Trojan horse taskkill.exe file. | |||||
CVE-2015-9266 | 2 Ubnt, Ui | 23 Airos 4 Xs2, Airos 4 Xs5, Edgeswitch Xp Firmware and 20 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
The web management interface of Ubiquiti airMAX, airFiber, airGateway and EdgeSwitch XP (formerly TOUGHSwitch) allows an unauthenticated attacker to upload and write arbitrary files using directory traversal techniques. An attacker can exploit this vulnerability to gain root privileges. This vulnerability is fixed in the following product versions (fixes released in July 2015, all prior versions are affected): airMAX AC 7.1.3; airMAX M (and airRouter) 5.6.2 XM/XW/TI, 5.5.11 XM/TI, and 5.5.10u2 XW; airGateway 1.1.5; airFiber AF24/AF24HD 2.2.1, AF5x 3.0.2.1, and AF5 2.2.1; airOS 4 XS2/XS5 4.0.4; and EdgeSwitch XP (formerly TOUGHSwitch) 1.3.2. | |||||
CVE-2014-2227 | 1 Ui | 1 Unifi Video | 2024-11-21 | 6.0 MEDIUM | N/A |
The default Flash cross-domain policy (crossdomain.xml) in Ubiquiti Networks UniFi Video (formerly AirVision aka AirVision Controller) before 3.0.1 does not restrict access to the application, which allows remote attackers to bypass the Same Origin Policy via a crafted SWF file. | |||||
CVE-2014-2226 | 1 Ui | 1 Unifi Controller | 2024-11-21 | 2.6 LOW | N/A |
Ubiquiti UniFi Controller before 3.2.1 logs the administrative password hash in syslog messages, which allows man-in-the-middle attackers to obtain sensitive information via unspecified vectors. | |||||
CVE-2013-3572 | 1 Ui | 1 Unifi | 2024-11-21 | 4.3 MEDIUM | N/A |
Cross-site scripting (XSS) vulnerability in the administer interface in the UniFi Controller in Ubiquiti Networks UniFi 2.3.5 and earlier allows remote attackers to inject arbitrary web script or HTML via a crafted client hostname. | |||||
CVE-2013-1606 | 1 Ui | 4 Aircam, Aircam Dome, Aircam Mini and 1 more | 2024-11-21 | 7.5 HIGH | N/A |
Buffer overflow in the ubnt-streamer RTSP service on the Ubiquiti UBNT AirCam with airVision firmware before 1.1.6 allows remote attackers to execute arbitrary code via a long rtsp: URI in a DESCRIBE request. | |||||
CVE-2023-31998 | 1 Ui | 4 Aircube, Aircube Firmware, Edgemax Edgerouter and 1 more | 2024-10-29 | N/A | 7.5 HIGH |
A heap overflow vulnerability found in EdgeRouters and Aircubes allows a malicious actor to interrupt UPnP service to said devices. | |||||
CVE-2024-42025 | 1 Ui | 1 Unifi Network Application | 2024-09-28 | N/A | 7.8 HIGH |
A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device. | |||||
CVE-2023-41721 | 1 Ui | 6 Unifi Dream Machine, Unifi Dream Machine Pro, Unifi Dream Machine Special Edition and 3 more | 2024-09-10 | N/A | 5.3 MEDIUM |
Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network. Affected Products: UDM UDM-PRO UDM-SE UDR UDW Mitigation: Update UniFi Network to Version 7.5.187 or later. | |||||
CVE-2023-1457 | 1 Ui | 2 Edgerouter X, Edgerouter X Firmware | 2024-08-02 | N/A | 9.8 CRITICAL |
** DISPUTED ** A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. Affected is an unknown function of the component Static Routing Configuration Handler. The manipulation of the argument next-hop-interface leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. VDB-223302 is the identifier assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities. | |||||
CVE-2023-1456 | 1 Ui | 2 Edgerouter X, Edgerouter X Firmware | 2024-08-02 | N/A | 9.8 CRITICAL |
A vulnerability, which was classified as critical, has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. This issue affects some unknown processing of the component NAT Configuration Handler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-223301 was assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities. | |||||
CVE-2023-2379 | 1 Ui | 4 Er-x, Er-x-sfp, Er-x-sfp Firmware and 1 more | 2024-05-17 | 7.8 HIGH | 7.5 HIGH |
A vulnerability classified as critical has been found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Service. The manipulation leads to denial of service. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-227655. | |||||
CVE-2023-2378 | 1 Ui | 4 Er-x, Er-x-sfp, Er-x-sfp Firmware and 1 more | 2024-05-17 | 6.5 MEDIUM | 8.8 HIGH |
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been rated as critical. Affected by this issue is some unknown functionality of the component Web Management Interface. The manipulation of the argument suffix-rate-up leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-227654 is the identifier assigned to this vulnerability. |