Filtered by vendor Silextechnology
Subscribe
Total
5 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-24486 | 1 Silextechnology | 2 Ds-600, Ds-600 Firmware | 2025-04-10 | N/A | 9.1 CRITICAL |
An issue discovered in silex technology DS-600 Firmware v.1.4.1 allows a remote attacker to edit device settings via the SAVE EEP_DATA command. | |||||
CVE-2024-24487 | 1 Silextechnology | 2 Ds-600, Ds-600 Firmware | 2025-04-10 | N/A | 6.8 MEDIUM |
An issue discovered in silex technology DS-600 Firmware v.1.4.1 allows a remote attacker to cause a denial of service via crafted UDP packets using the EXEC REBOOT SYSTEM command. | |||||
CVE-2024-24485 | 1 Silextechnology | 2 Ds-600, Ds-600 Firmware | 2025-04-10 | N/A | 7.5 HIGH |
An issue discovered in silex technology DS-600 Firmware v.1.4.1 allows a remote attacker to obtain sensitive information via the GET EEP_DATA command. | |||||
CVE-2018-6021 | 1 Silextechnology | 4 Geh-sd-320an, Geh-sd-320an Firmware, Sd-320an and 1 more | 2024-11-21 | 6.5 MEDIUM | 7.4 HIGH |
Silex SD-320AN version 2.01 and prior and GE MobileLink(GEH-SD-320AN) version GEH-1.1 and prior have a system call parameter that is not properly sanitized, which may allow remote code execution. | |||||
CVE-2018-6020 | 1 Silextechnology | 8 Geh-500, Geh-500 Firmware, Geh-sd-320an and 5 more | 2024-11-21 | 6.4 MEDIUM | 6.5 MEDIUM |
In Silex SX-500 all versions and GE MobileLink(GEH-500) version 1.54 and prior, authentication is not verified when making certain POST requests, which may allow attackers to modify system settings. |