Filtered by vendor Sick
Subscribe
Total
65 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-27583 | 1 Sick | 4 Flx3-cpuc1, Flx3-cpuc1 Firmware, Flx3-cpuc2 and 1 more | 2025-05-07 | N/A | 9.1 CRITICAL |
A remote unprivileged attacker can interact with the configuration interface of a Flexi-Compact FLX3-CPUC1 or FLX3-CPUC2 running an affected firmware version to potentially impact the availability of the FlexiCompact. | |||||
CVE-2022-27586 | 1 Sick | 2 Sim1004-0p0g311, Sim1004-0p0g311 Firmware | 2025-05-06 | N/A | 9.8 CRITICAL |
Password recovery vulnerability in SICK SIM1004 Partnumber 1098148 with firmware version <2.0.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.0.0 as soon as possible (available in SICK Support Portal). | |||||
CVE-2022-27584 | 1 Sick | 2 Sim2000st, Sim2000st Firmware | 2025-05-06 | N/A | 9.8 CRITICAL |
Password recovery vulnerability in SICK SIM2000ST Partnumber 1080579 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.7.0 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM2000ST. A fix is planned but not yet scheduled. | |||||
CVE-2022-27582 | 1 Sick | 14 Sim1000 Fx, Sim1000 Fx Firmware, Sim1004 and 11 more | 2025-05-06 | N/A | 9.8 CRITICAL |
Password recovery vulnerability in SICK SIM4000 (PPC) Partnumber 1078787 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.10.1 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM4000. A fix is planned but not yet scheduled. | |||||
CVE-2022-43990 | 1 Sick | 2 Sim1012-0p0g200, Sim1012-0p0g200 Firmware | 2025-05-05 | N/A | 7.3 HIGH |
Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version <2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.2.0 as soon as possible (available in SICK Support Portal). | |||||
CVE-2022-43989 | 1 Sick | 4 Sim2000-2p04g10, Sim2000-2p04g10 Firmware, Sim2500-2p03g10 and 1 more | 2025-05-05 | N/A | 7.3 HIGH |
Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.2.0 as soon as possible (available in SICK Support Portal). | |||||
CVE-2022-27585 | 1 Sick | 2 Sim1000 Fx, Sim1000 Fx Firmware | 2025-05-02 | N/A | 9.8 CRITICAL |
Password recovery vulnerability in SICK SIM1000 FX Partnumber 1097816 and 1097817 with firmware version <1.6.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.6.0 as soon as possible (available in SICK Support Portal). | |||||
CVE-2022-27581 | 1 Sick | 24 Rfu610-10600, Rfu610-10600 Firmware, Rfu610-10601 and 21 more | 2025-04-22 | N/A | 6.5 MEDIUM |
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU61x firmware version <v2.25 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person. | |||||
CVE-2022-46834 | 1 Sick | 14 Rfu650-10100, Rfu650-10100 Firmware, Rfu650-10101 and 11 more | 2025-04-22 | N/A | 6.5 MEDIUM |
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version < v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person. | |||||
CVE-2022-46833 | 1 Sick | 48 Rfu630-04100, Rfu630-04100 Firmware, Rfu630-04100s01 and 45 more | 2025-04-22 | N/A | 6.5 MEDIUM |
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU63x firmware version < v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person. | |||||
CVE-2022-46832 | 1 Sick | 42 Rfu620-10100, Rfu620-10100 Firmware, Rfu620-10101 and 39 more | 2025-04-21 | N/A | 6.5 MEDIUM |
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU62x firmware version < 2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person. | |||||
CVE-2022-47377 | 1 Sick | 2 Sim2000 Firmware, Sim2000st | 2025-04-16 | N/A | 9.8 CRITICAL |
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal). | |||||
CVE-2023-23453 | 1 Sick | 4 Fx0-gent00000, Fx0-gent00000 Firmware, Fx0-gent00010 and 1 more | 2025-03-18 | N/A | 9.8 CRITICAL |
Missing Authentication for Critical Function in SICK FX0-GENT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000. | |||||
CVE-2023-23452 | 1 Sick | 4 Fx0-gpnt00000, Fx0-gpnt00000 Firmware, Fx0-gpnt00010 and 1 more | 2025-03-18 | N/A | 9.8 CRITICAL |
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000. | |||||
CVE-2023-23451 | 1 Sick | 20 Fx0-gent00000, Fx0-gent00000 Firmware, Fx0-gent00030 and 17 more | 2025-02-05 | N/A | 9.8 CRITICAL |
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW., SICK UE410-EN1 FLEXI ETHERNET GATEW., SICK UE410-EN3S04 FLEXI ETHERNET GATEW., SICK UE410-EN4 FLEXI ETHERNET GATEW., SICK FX0-GENT00000 FLEXISOFT EIP GATEW., SICK FX0-GMOD00000 FLEXISOFT MOD GATEW., SICK FX0-GPNT00000 FLEXISOFT PNET GATEW., SICK FX0-GENT00030 FLEXISOFT EIP GATEW.V2, SICK FX0-GPNT00030 FLEXISOFT PNET GATEW.V2 and SICK FX0-GMOD00010 FLEXISOFT MOD GW. have Telnet enabled by factory default. No password is set in the default configuration. Gateways with a serial number >2311xxxx have the Telnet interface disabled by factory default. | |||||
CVE-2023-23444 | 1 Sick | 22 Fx0-gent00000, Fx0-gent00000 Firmware, Fx0-gent00010 and 19 more | 2025-01-24 | N/A | 7.5 HIGH |
Missing Authentication for Critical Function in SICK Flexi Classic and Flexi Soft Gateways with Partnumbers 1042193, 1042964, 1044078, 1044072, 1044073, 1044074, 1099830, 1099832, 1127717, 1069070, 1112296, 1051432, 1102420, 1127487, 1121596, 1121597 allows an unauthenticated remote attacker to influence the availability of the device by changing the IP settings of the device via broadcasted UDP packets. | |||||
CVE-2023-5288 | 1 Sick | 2 Sim1012-0p0g200, Sim1012-0p0g200 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
A remote unauthorized attacker may connect to the SIM1012, interact with the device and change configuration settings. The adversary may also reset the SIM and in the worst case upload a new firmware version to the device. | |||||
CVE-2023-5246 | 1 Sick | 26 Fx0-gent00000, Fx0-gent00000 Firmware, Fx0-gent00010 and 23 more | 2024-11-21 | N/A | 8.8 HIGH |
Authentication Bypass by Capture-replay in SICK Flexi Soft Gateways with Partnumbers 1044073, 1127717, 1130282, 1044074, 1121597, 1099832, 1051432, 1127487, 1069070, 1112296, 1044072, 1121596, 1099830 allows an unauthenticated remote attacker to potentially impact the availability, integrity and confidentiality of the gateways via an authentication bypass by capture-replay. | |||||
CVE-2023-5103 | 1 Sick | 2 Apu0200, Apu0200 Firmware | 2024-11-21 | N/A | 4.3 MEDIUM |
Improper Restriction of Rendered UI Layers or Frames in RDT400 in SICK APU allows an unprivileged remote attacker to potentially reveal sensitive information via tricking a user into clicking on an actionable item using an iframe. | |||||
CVE-2023-5102 | 1 Sick | 2 Apu0200, Apu0200 Firmware | 2024-11-21 | N/A | 5.3 MEDIUM |
Insufficient Control Flow Management in RDT400 in SICK APU allows an unprivileged remote attacker to potentially enable hidden functionality via HTTP requests. |