Filtered by vendor Schneider Electric
Subscribe
Total
7 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-9631 | 1 Schneider Electric | 1 Wonderware Archestra Logger | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A Null Pointer Dereference issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The null pointer dereference vulnerability could allow an attacker to crash the logger process, causing a denial of service for logging and log-viewing (applications that use the Wonderware ArchestrA Logger continue to run when the Wonderware ArchestrA Logger service is unavailable). | |||||
CVE-2017-5157 | 2 Schneider-electric, Schneider Electric | 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code. | |||||
CVE-2014-9188 | 1 Schneider Electric | 1 Proclima | 2024-11-21 | 9.0 HIGH | N/A |
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers. | |||||
CVE-2014-8514 | 1 Schneider Electric | 1 Proclima | 2024-11-21 | 7.5 HIGH | N/A |
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. | |||||
CVE-2014-8513 | 1 Schneider Electric | 1 Proclima | 2024-11-21 | 7.5 HIGH | N/A |
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. | |||||
CVE-2014-8512 | 1 Schneider Electric | 1 Proclima | 2024-11-21 | 7.5 HIGH | N/A |
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers. | |||||
CVE-2013-0662 | 2 Schneider-electric, Schneider Electric | 13 Concept, Modbus Serial Driver, Modbuscommdtm Sl and 10 more | 2024-11-21 | 9.3 HIGH | N/A |
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. |