Vulnerabilities (CVE)

Filtered by vendor Ni Subscribe
Total 24 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-5136 1 Ni 4 Diadem, Flexlogger, Topografix Data Plugin and 1 more 2024-10-10 N/A 5.5 MEDIUM
An incorrect permission assignment in the TopoGrafix DataPlugin for GPX could result in information disclosure. An attacker could exploit this vulnerability by getting a user to open a specially crafted data file.
CVE-2024-6791 1 Ni 1 Veristand 2024-09-17 N/A 7.8 HIGH
A directory path traversal vulnerability exists when loading a vsmodel file in NI VeriStand that may result in remote code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .vsmodel file. This vulnerability affects VeriStand 2024 Q2 and prior versions.
CVE-2024-6793 1 Ni 1 Veristand 2024-09-17 N/A 9.8 CRITICAL
A deserialization of untrusted data vulnerability exists in NI VeriStand DataLogging Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions.
CVE-2024-6794 1 Ni 1 Veristand 2024-09-17 N/A 9.8 CRITICAL
A deserialization of untrusted data vulnerability exists in NI VeriStand Waveform Streaming Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions.
CVE-2024-6805 1 Ni 1 Veristand 2024-09-17 N/A 9.8 CRITICAL
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access File Transfer resources. These missing checks may result in information disclosure or remote code execution. This affects NI VeriStand 2024 Q2 and prior versions.
CVE-2024-6806 1 Ni 1 Veristand 2024-09-17 N/A 9.8 CRITICAL
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access Project resources. These missing checks may result in remote code execution. This affects NI VeriStand 2024 Q2 and prior versions.
CVE-2024-6121 1 Ni 2 Flexlogger, Systemlink 2024-09-12 N/A 7.8 HIGH
An out-of-date version of Redis shipped with NI SystemLink Server is susceptible to multiple vulnerabilities, including CVE-2022-24834. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service.
CVE-2024-4081 1 Ni 1 Labview 2024-09-12 N/A 7.8 HIGH
A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions.
CVE-2024-6122 1 Ni 2 Flexlogger, Systemlink 2024-09-10 N/A 5.5 MEDIUM
An incorrect permission in the installation directory for the shared NI SystemLink Server KeyValueDatabase service may result in information disclosure via local access. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service.
CVE-2024-4080 1 Ni 1 Labview 2024-09-05 N/A 7.8 HIGH
A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
CVE-2024-4079 1 Ni 1 Labview 2024-09-05 N/A 7.8 HIGH
An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
CVE-2022-35415 1 Ni 1 Configuration Manager 2024-02-04 N/A 7.8 HIGH
An improper input validation in NI System Configuration Manager before 22.5 may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2022-27237 1 Ni 5 Flexlogger, G Web Development Software, Labview and 2 more 2024-02-04 4.3 MEDIUM 6.1 MEDIUM
There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later.
CVE-2021-42563 2 Microsoft, Ni 2 Windows, Ni Service Locator 2024-02-04 4.6 MEDIUM 7.8 HIGH
There is an Unquoted Service Path in NI Service Locator (nisvcloc.exe) in versions prior to 18.0 on Windows. This may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges.
CVE-2021-38304 1 Ni 1 Ni-pal 2024-02-04 4.6 MEDIUM 7.8 HIGH
Improper input validation in the National Instruments NI-PAL driver in versions 20.0.0 and prior may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2020-25191 1 Ni 2 Compactrio, Compactrio Firmware 2024-02-04 7.8 HIGH 7.5 HIGH
Incorrect permissions are set by default for an API entry-point of a specific service, allowing a non-authenticated user to trigger a function that could reboot the CompactRIO (Driver versions prior to 20.5) remotely.
CVE-2017-2779 1 Ni 1 Labview 2024-02-04 6.8 MEDIUM 7.8 HIGH
An exploitable memory corruption vulnerability exists in the RSRC segment parsing functionality of LabVIEW 2017, LabVIEW 2016, LabVIEW 2015, and LabVIEW 2014. A specially crafted Virtual Instrument (VI) file can cause an attacker controlled looping condition resulting in an arbitrary null write. An attacker controlled VI file can be used to trigger this vulnerability and can potentially result in code execution.
CVE-2017-2775 1 Ni 1 Labview 2024-02-04 6.8 MEDIUM 7.8 HIGH
An exploitable memory corruption vulnerability exists in the LvVariantUnflatten functionality in 64-bit versions of LabVIEW before 2015 SP1 f7 Patch and 2016 before f2 Patch. A specially crafted VI file can cause a user controlled value to be used as a loop terminator resulting in internal heap corruption. An attacker controlled VI file can be used to trigger this vulnerability, exploitation could lead to remote code execution.
CVE-2013-5024 1 Ni 1 Measurementstudio 2024-02-04 4.3 MEDIUM N/A
An ActiveX control in NationalInstruments.Help2.dll in National Instruments NI .NET Class Library Help, as used in Measurement Studio 2013 and earlier and other products, allows remote attackers to obtain sensitive information about the existence of registry keys via crafted (1) key-open or (2) key-close method calls.
CVE-2013-5021 2 Abb, Ni 5 Datamanager, Labview, Labwindows and 2 more 2024-02-04 9.3 HIGH N/A
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.