Filtered by vendor Gehealthcare
Subscribe
Total
34 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2010-5308 | 1 Gehealthcare | 1 Optima Mr360 Firmware | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via an arbitrary username in the Emergency Login screen. NOTE: this might not qualify for inclusion in CVE if unauthenticated emergency access is part of the intended security policy of the product, can be controlled by the system administrator, and is not enabled by default. | |||||
CVE-2001-1594 | 1 Gehealthcare | 1 Entegra P\&r | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare eNTEGRA P&R has a password of (1) entegra for the entegra user, (2) passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, (3) 0 for the entegra user of the Codonics printer FTP service, (4) eNTEGRA for the eNTEGRA P&R user account, (5) insite for the WinVNC Login, and possibly other accounts, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2002-2446 | 1 Gehealthcare | 3 Millennium Mg Firmware, Millennium Myosight Firmware, Millennium Nc Firmware | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Millennium MG, NC, and MyoSIGHT has a password of insite.genieacq for the insite account that cannot be changed without disabling product functionality for remote InSite support, which has unspecified impact and attack vectors. | |||||
CVE-2010-5309 | 1 Gehealthcare | 1 Cadstream Server Firmware | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors. | |||||
CVE-2011-5324 | 1 Gehealthcare | 1 Centricity Pacs-iw | 2025-04-12 | 10.0 HIGH | N/A |
The TeraRecon server, as used in GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions, has a password of (1) shared for the shared user and (2) scan for the scan user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2013-7405 | 1 Gehealthcare | 1 Centricity Dms | 2025-04-12 | 10.0 HIGH | N/A |
The Ad Hoc Reporting feature in GE Healthcare Centricity DMS 4.2 has a password of Never!Mind for the Administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2006-7253 | 1 Gehealthcare | 1 Infinia Ii | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Infinia II has a default password of (1) infinia for the infinia user, (2) #bigguy1 for the acqservice user, (3) dont4get2 for the Administrator user, (4) #bigguy1 for the emergency user, and (5) 2Bfamous for the InfiniaAdmin user, which has unspecified impact and attack vectors. | |||||
CVE-2010-5306 | 1 Gehealthcare | 3 Optima Ct520 Firmware, Optima Ct540 Firmware, Optima Ct680 Firmware | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors. | |||||
CVE-2011-5322 | 1 Gehealthcare | 1 Centricity Analytics Server | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Centricity Analytics Server 1.1 has a default password of (1) V0yag3r for the SQL Server sa user, (2) G3car3s for the analyst user, (3) G3car3s for the ccg user, (4) V0yag3r for the viewer user, and (5) geservice for the geservice user in the Webmin interface, which has unspecified impact and attack vectors. | |||||
CVE-2010-5310 | 1 Gehealthcare | 1 Revolution Xq\/i | 2025-04-12 | 10.0 HIGH | N/A |
The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2003-1603 | 1 Gehealthcare | 1 Discovery Vh | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors. | |||||
CVE-2013-7442 | 1 Gehealthcare | 1 Centricity Pacs Workstation | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of (1) CANal1 for the Administrator user and (2) iis for the IIS user, which has unspecified impact and attack vectors related to TimbuktuPro. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires it. | |||||
CVE-2014-9736 | 1 Gehealthcare | 1 Centricity Clinical Archive Audit Trail Repository | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Centricity Clinical Archive Audit Trail Repository has a default password of initinit for the (1) SSL key manager and (2) server keystore; (3) keystore_password for the server truststore; and atna for the (4) primary storage database and (5) archive storage database, which has unspecified impact and attack vectors. | |||||
CVE-2011-5323 | 1 Gehealthcare | 1 Centricity Pacs-iw | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions has a password of A11enda1e for the sa SQL server user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2012-6660 | 1 Gehealthcare | 1 Precision Mpi | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Precision MPi has a password of (1) orion for the serviceapp user, (2) orion for the clinical operator user, and (3) PlatinumOne for the administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2013-7404 | 1 Gehealthcare | 1 Discovery Nm 750b | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Discovery NM 750b has a password of 2getin for the insite account for (1) Telnet and (2) FTP, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2014-7232 | 1 Gehealthcare | 2 Discovery Xr656, Discovery Xr656 G2 | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Discovery XR656 and XR656 G2 has a password of (1) 2getin for the insite user, (2) 4$xray for the xruser user, and (3) #superxr for the root user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2010-5307 | 1 Gehealthcare | 1 Optima Mr360 Firmware | 2025-04-12 | 10.0 HIGH | N/A |
The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. | |||||
CVE-2002-2445 | 1 Gehealthcare | 3 Millennium Mg, Millennium Myosight, Millennium Nc | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Millennium MG, NC, and MyoSIGHT has a default password of (1) root.genie for the root user, (2) "service." for the service user, (3) admin.genie for the admin user, (4) reboot for the reboot user, and (5) shutdown for the shutdown user, which has unspecified impact and attack vectors. | |||||
CVE-2012-6693 | 1 Gehealthcare | 1 Centricity Pacs Server | 2025-04-12 | 10.0 HIGH | N/A |
GE Healthcare Centricity PACS 4.0 Server has a default password of (1) nasro for the nasro (ReadOnly) user and (2) nasrw for the nasrw (Read/Write) user, which has unspecified impact and attack vectors. |