Filtered by vendor Aveva
Subscribe
Total
53 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-34348 | 1 Aveva | 1 Pi Server | 2024-02-05 | N/A | 7.5 HIGH |
AVEVA PI Server versions 2023 and 2018 SP3 P05 and prior contain a vulnerability that could allow an unauthenticated user to remotely crash the PI Message Subsystem of a PI Server, resulting in a denial-of-service condition. | |||||
CVE-2023-31274 | 1 Aveva | 1 Pi Server | 2024-02-05 | N/A | 5.3 MEDIUM |
AVEVA PI Server versions 2023 and 2018 SP3 P05 and prior contain a vulnerability that could allow an unauthenticated user to cause the PI Message Subsystem of a PI Server to consume available memory resulting in throttled processing of new PI Data Archive events and a partial denial-of-service condition. | |||||
CVE-2021-42796 | 1 Aveva | 1 Edge | 2024-02-05 | N/A | 9.8 CRITICAL |
An issue was discovered in ExecuteCommand() in AVEVA Edge (formerly InduSoft Web Studio) versions R2020 and prior that allows unauthenticated arbitrary commands to be executed. | |||||
CVE-2021-42797 | 1 Aveva | 1 Edge | 2024-02-05 | N/A | 7.5 HIGH |
Path traversal vulnerability in AVEVA Edge (formerly InduSoft Web Studio) versions R2020 and prior allows an unauthenticated user to steal the Windows access token of the user account configured for accessing external DB resources. | |||||
CVE-2023-33873 | 1 Aveva | 13 Batch Management, Communication Drivers, Edge and 10 more | 2024-02-05 | N/A | 7.8 HIGH |
This privilege escalation vulnerability, if exploited, cloud allow a local OS-authenticated user with standard privileges to escalate to System privilege on the machine where these products are installed, resulting in complete compromise of the target machine. | |||||
CVE-2023-34982 | 1 Aveva | 13 Batch Management, Communication Drivers, Edge and 10 more | 2024-02-05 | N/A | 7.1 HIGH |
This external control vulnerability, if exploited, could allow a local OS-authenticated user with standard privileges to delete files with System privilege on the machine where these products are installed, resulting in denial of service. | |||||
CVE-2021-42794 | 1 Aveva | 1 Edge | 2024-02-05 | N/A | 5.3 MEDIUM |
An issue was discovered in AVEVA Edge (formerly InduSoft Web Studio) versions R2020 and prior. The application allows a client to provide a malicious connection string that could allow an adversary to port scan the LAN, depending on the hosts' responses. | |||||
CVE-2022-23854 | 1 Aveva | 1 Intouch Access Anywhere | 2024-02-04 | N/A | 7.5 HIGH |
AVEVA InTouch Access Anywhere versions 2020 R2 and older are vulnerable to a path traversal exploit that could allow an unauthenticated user with network access to read files on the system outside of the secure gateway web server. | |||||
CVE-2023-1256 | 1 Aveva | 2 Aveva Plant Scada, Telemetry Server | 2024-02-04 | N/A | 9.8 CRITICAL |
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states. | |||||
CVE-2021-38410 | 1 Aveva | 7 Batch Management, Enterprise Data Management, Manufacturing Execution System and 4 more | 2024-02-04 | N/A | 7.8 HIGH |
AVEVA Software Platform Common Services (PCS) Portal versions 4.5.2, 4.5.1, 4.5.0, and 4.4.6 are vulnerable to DLL hijacking through an uncontrolled search path element, which may allow an attacker control to one or more locations in the search path. | |||||
CVE-2022-0835 | 1 Aveva | 1 System Platform | 2024-02-04 | 1.9 LOW | 5.5 MEDIUM |
AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user. | |||||
CVE-2021-33008 | 1 Aveva | 1 System Platform | 2024-02-04 | 7.5 HIGH | 9.8 CRITICAL |
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity. | |||||
CVE-2022-1467 | 1 Aveva | 2 Intouch Access Anywhere, Plant Scada Access Anywhere | 2024-02-04 | 8.5 HIGH | 9.9 CRITICAL |
Windows OS can be configured to overlay a “language bar” on top of any application. When this OS functionality is enabled, the OS language bar UI will be viewable in the browser alongside the AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere applications. It is possible to manipulate the Windows OS language bar to launch an OS command prompt, resulting in a context-escape from application into OS. | |||||
CVE-2021-32985 | 1 Aveva | 1 System Platform | 2024-02-04 | 6.5 MEDIUM | 7.2 HIGH |
AVEVA System Platform versions 2017 through 2020 R2 P01 does not properly verify that the source of data or communication is valid. | |||||
CVE-2021-32977 | 1 Aveva | 1 System Platform | 2024-02-04 | 6.5 MEDIUM | 7.2 HIGH |
AVEVA System Platform versions 2017 through 2020 R2 P01 does not verify, or incorrectly verifies, the cryptographic signature for data. | |||||
CVE-2021-33010 | 1 Aveva | 1 System Platform | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
An exception is thrown from a function in AVEVA System Platform versions 2017 through 2020 R2 P01, but it is not caught, which may cause a denial-of-service condition. | |||||
CVE-2021-32981 | 1 Aveva | 1 System Platform | 2024-02-04 | 6.5 MEDIUM | 7.2 HIGH |
AVEVA System Platform versions 2017 through 2020 R2 P01 uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the software does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory. | |||||
CVE-2021-32979 | 1 Aveva | 1 Suitelink | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
Null pointer dereference in SuiteLink server while processing commands 0x04/0x0a | |||||
CVE-2021-32999 | 1 Aveva | 1 Suitelink | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
Improper handling of exceptional conditions in SuiteLink server while processing command 0x01 | |||||
CVE-2021-32987 | 1 Aveva | 1 Suitelink | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
Null pointer dereference in SuiteLink server while processing command 0x0b |