CVE-2021-22285 1 Abb 4 Pni800, Pni800 Firmware, Spiet800 and 1 more 2024-02-04 5.0 MEDIUM 7.5 HIGH
Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive.
CVE-2020-24672 1 Abb 1 Base Software 2024-02-04 6.8 MEDIUM 9.8 CRITICAL
A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
CVE-2021-22284 1 Abb 1 Opc Server For Ac 800m 2024-02-04 6.5 MEDIUM 8.8 HIGH
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server.
CVE-2020-24678 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 6.5 MEDIUM 8.8 HIGH
An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian database is affected by multiple vulnerabilities such as the possibility to allow remote authenticated users to gain high privileges.
CVE-2020-24673 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 7.5 HIGH 9.8 CRITICAL
In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file system and in some cases issue commands to the operating system. This can lead to a loss of confidentiality and data integrity or even affect the product behavior and its availability.
CVE-2020-24686 1 Abb 12 Pm554, Pm554 Firmware, Pm556 and 9 more 2024-02-04 5.0 MEDIUM 7.5 HIGH
The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and refuse connections to Automation Builder. The execution of the PLC application is not affected by this vulnerability. This issue affects ABB AC500 V2 products with onboard Ethernet.
CVE-2020-24674 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 9.0 HIGH 8.8 HIGH
In S+ Operations and S+ Historian, not all client commands correctly check user permission as expected. Authenticated but Unauthorized remote users could execute a Denial-of-Service (DoS) attack, execute arbitrary code, or obtain more privilege than intended on the machines.
CVE-2020-24677 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 6.5 MEDIUM 8.8 HIGH
Vulnerabilities in the S+ Operations and S+ Historian web applications can lead to a possible code execution and privilege escalation, redirect the user somewhere else or download unwanted data.
CVE-2020-24685 1 Abb 3 Ac500 Cpu Firmware, Pm573-eth, Pm583-eth 2024-02-04 5.0 MEDIUM 8.6 HIGH
An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service (DoS) vulnerability. Vulnerability allows attacker to stop the PLC. After stopping (ERR LED flashing red), physical access to the PLC is required in order to restart the application. This issue affects: ABB AC500 V2 products with onboard Ethernet version 2.8.4 and prior versions.
CVE-2020-24680 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 4.6 MEDIUM 7.0 HIGH
In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database.
CVE-2020-24676 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 4.6 MEDIUM 7.8 HIGH
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
CVE-2020-24679 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 10.0 HIGH 9.8 CRITICAL
A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted.
CVE-2020-24675 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 7.5 HIGH 9.8 CRITICAL
In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.
CVE-2020-24683 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2024-02-04 7.5 HIGH 9.8 CRITICAL
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application.
CVE-2020-8485 1 Abb 1 800xa 2024-02-04 4.6 MEDIUM 7.8 HIGH
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
CVE-2020-8489 1 Abb 1 800xa Information Management 2024-02-04 4.6 MEDIUM 7.8 HIGH
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable.
CVE-2020-8474 1 Abb 1 800xa Base System 2024-02-04 4.6 MEDIUM 7.8 HIGH
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.
CVE-2019-19105 2 Abb, Busch-jaeger 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more 2024-02-04 2.1 LOW 5.5 MEDIUM
The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.
CVE-2020-8478 1 Abb 4 Ac800m, Base Software, Mms Server and 1 more 2024-02-04 2.1 LOW 3.3 LOW
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
CVE-2020-8475 1 Abb 3 800xa System, Compact Hmi, Control Builder Safe 2024-02-04 2.1 LOW 7.5 HIGH
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service.