Vulnerabilities (CVE)

Filtered by vendor Abb Subscribe
Total 124 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-0635 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2024-09-19 N/A 9.8 CRITICAL
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
CVE-2022-31217 1 Abb 3 Automation Builder, Drive Composer, Mint Workbench 2024-09-17 7.2 HIGH 7.8 HIGH
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
CVE-2022-31219 1 Abb 3 Automation Builder, Drive Composer, Mint Workbench 2024-09-16 7.2 HIGH 7.8 HIGH
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
CVE-2022-31218 1 Abb 3 Automation Builder, Drive Composer, Mint Workbench 2024-09-16 7.2 HIGH 7.8 HIGH
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
CVE-2022-31216 1 Abb 3 Automation Builder, Drive Composer, Mint Workbench 2024-09-16 7.2 HIGH 7.8 HIGH
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
CVE-2024-5402 1 Abb 1 Mint Workbench 2024-07-19 N/A 7.8 HIGH
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868.
CVE-2024-6209 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2024-07-08 N/A 7.5 HIGH
Unauthorized file access in WEB Server in ABB ASPECT - Enterprise v <=3.08.01; NEXUS Series v <=3.08.01 ; MATRIX Series v<=3.08.01 allows Attacker to access files unauthorized
CVE-2024-6298 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2024-07-08 N/A 9.8 CRITICAL
Improper Input Validation vulnerability in ABB ASPECT-Enterprise on Linux, ABB NEXUS Series on Linux, ABB MATRIX Series on Linux allows Remote Code Inclusion.This issue affects ASPECT-Enterprise: through 3.08.01; NEXUS Series: through 3.08.01; MATRIX Series: through 3.08.01.
CVE-2024-4009 1 Abb 10 2tma310010b0001, 2tma310010b0001 Firmware, 2tma310010b0003 and 7 more 2024-06-18 N/A 7.8 HIGH
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
CVE-2024-4008 1 Abb 10 2tma310010b0001, 2tma310010b0001 Firmware, 2tma310010b0003 and 7 more 2024-06-18 N/A 8.8 HIGH
FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System
CVE-2022-2513 1 Abb 12 Gms600, Gms600 Firmware, Pcm600 and 9 more 2024-05-28 N/A 5.5 MEDIUM
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs.
CVE-2023-3324 1 Abb 1 Zenon 2024-02-05 N/A 7.5 HIGH
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
CVE-2023-0425 1 Abb 6 Ac700f, Ac700f Firmware, Ac900f and 3 more 2024-02-05 N/A 7.5 HIGH
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible.  Numeric Range Comparison Without Minimum Check vulnerability in ABB Freelance controllers AC 700F (Controller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F:  from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1;  Freelance controllers AC 900F:  Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1.
CVE-2023-2685 1 Abb 1 Ao-opc 2024-02-05 N/A 6.3 MEDIUM
A vulnerability was found in AO-OPC server versions mentioned above. As the directory information for the service entry is not enclosed in quotation marks, potential attackers could possibly call up another application than the AO-OPC server by starting the service. The service might be started with system user privileges which could cause a shift in user access privileges. It is unlikely to exploit the vulnerability in well maintained Windows installations since the attacker would need write access to system folders. An update is available that resolves the vulnerability found during an internal review in the product AO-OPC = 3.2.1 
CVE-2023-3322 1 Abb 1 Zenon 2024-02-05 N/A 8.1 HIGH
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
CVE-2023-0426 1 Abb 6 Ac700f, Ac700f Firmware, Ac900f and 3 more 2024-02-05 N/A 7.5 HIGH
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Stack-based Buffer Overflow vulnerability in ABB Freelance controllers AC 700F (conroller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects:  Freelance controllers AC 700F:  from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019 , through Freelance 2019 SP1, through Freelance 2019 SP1 FP1;  Freelance controllers AC 900F:  through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1.
CVE-2023-3323 1 Abb 1 Zenon 2024-02-05 N/A 5.4 MEDIUM
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
CVE-2023-3321 1 Abb 1 Zenon 2024-02-05 N/A 8.8 HIGH
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
CVE-2023-2625 1 Abb 2 Txpert Hub Coretec 4, Txpert Hub Coretec 4 Firmware 2024-02-04 N/A 8.0 HIGH
A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system.
CVE-2023-0863 1 Abb 16 Terra Ac Wallbox 80a, Terra Ac Wallbox 80a Firmware, Terra Ac Wallbox Ce Juno and 13 more 2024-02-04 N/A 8.8 HIGH
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.