Vulnerabilities (CVE)

Filtered by vendor Abb Subscribe
Total 124 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-0228 1 Abb 1 Symphony Plus S\+ Operations 2024-11-21 N/A 8.8 HIGH
Improper Authentication vulnerability in ABB Symphony Plus S+ Operations.This issue affects Symphony Plus S+ Operations: from 2.X through 2.1 SP2, 2.2, from 3.X through 3.3 SP1, 3.3 SP2.
CVE-2022-4126 4 Abb, Apple, Linux and 1 more 4 Rccmd, Macos, Linux Kernel and 1 more 2024-11-21 N/A 9.6 CRITICAL
Use of Default Password vulnerability in ABB RCCMD on Windows, Linux, MacOS allows Try Common or Default Usernames and Passwords.This issue affects RCCMD: before 4.40 230207.
CVE-2022-3573 2 Abb, Gitlab 2 Drive Composer, Gitlab 2024-11-21 N/A 5.4 MEDIUM
An issue has been discovered in GitLab CE/EE affecting all versions starting from 15.4 before 15.5.7, all versions starting from 15.6 before 15.6.4, all versions starting from 15.7 before 15.7.2. Due to the improper filtering of query parameters in the wiki changes page, an attacker can execute arbitrary JavaScript on the self-hosted instances running without strict CSP.
CVE-2022-3388 1 Abb 1 Microscada Pro Sys600 2024-11-21 N/A 8.8 HIGH
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. An authenticated user can launch an administrator level remote code execution irrespective of the authenticated user's role.
CVE-2022-34838 1 Abb 1 Zenon 2024-11-21 N/A 8.1 HIGH
Storing Passwords in a Recoverable Format vulnerability in ABB Zenon 8.20 allows an attacker who successfully exploit the vulnerability may add or alter data points and corresponding attributes. Once such engineering data is used the data visualization will be altered for the end user.
CVE-2022-34836 1 Abb 1 Zenon 2024-11-21 N/A 5.9 MEDIUM
Relative Path Traversal vulnerability in ABB Zenon 8.20 allows the user to access files on the Zenon system and user also can add own log messages and e.g., flood the log entries. An attacker who successfully exploit the vulnerability could access the Zenon runtime activities such as the start and stop of various activity and the last error code etc.
CVE-2022-31219 1 Abb 3 Automation Builder, Drive Composer, Mint Workbench 2024-11-21 7.2 HIGH 7.3 HIGH
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
CVE-2022-31218 1 Abb 3 Automation Builder, Drive Composer, Mint Workbench 2024-11-21 7.2 HIGH 7.8 HIGH
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
CVE-2022-31217 1 Abb 3 Automation Builder, Drive Composer, Mint Workbench 2024-11-21 7.2 HIGH 7.8 HIGH
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
CVE-2022-31216 1 Abb 3 Automation Builder, Drive Composer, Mint Workbench 2024-11-21 7.2 HIGH 7.8 HIGH
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
CVE-2022-2513 1 Abb 12 Gms600, Gms600 Firmware, Pcm600 and 9 more 2024-11-21 N/A 7.1 HIGH
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs.
CVE-2022-28702 1 Abb 1 E-design 2024-11-21 4.9 MEDIUM 6.1 MEDIUM
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
CVE-2022-28613 2 Abb, Hitachienergy 3 Rtu500 Firmware, Rtu500, Rtu500 Firmware 2024-11-21 7.8 HIGH 7.5 HIGH
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.
CVE-2022-26080 1 Abb 14 H5692448 G104, H5692448 G104 Firmware, H5692448 G224l and 11 more 2024-11-21 N/A 6.3 MEDIUM
Use of Insufficiently Random Values vulnerability in ABB Pulsar Plus System Controller NE843_S, ABB Infinity DC Power Plant.This issue affects Pulsar Plus System Controller NE843_S : comcode 150042936; Infinity DC Power Plant: H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415.
CVE-2022-26057 1 Abb 1 Mint Workbench 2024-11-21 7.2 HIGH 6.7 MEDIUM
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
CVE-2022-1607 1 Abb 2 Infinity Dc Power Plant, Ne843 S 2024-11-21 N/A 4.6 MEDIUM
Cross-Site Request Forgery (CSRF) vulnerability in ABB Pulsar Plus System Controller NE843_S, ABB Infinity DC Power Plant allows Cross Site Request Forgery.This issue affects Pulsar Plus System Controller NE843_S : comcode 150042936; Infinity DC Power Plant: H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415.
CVE-2022-1596 1 Abb 6 Rex640 Pcl1, Rex640 Pcl1 Firmware, Rex640 Pcl2 and 3 more 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node.
CVE-2022-0947 1 Abb 48 Arc600a2323na, Arc600a2323na Firmware, Arc600a2324na and 45 more 2024-11-21 6.8 MEDIUM 9.0 CRITICAL
A vulnerability in ABB ARG600 Wireless Gateway series that could allow an attacker to exploit the vulnerability by remotely connecting to the serial port gateway, and/or protocol converter, depending on the configuration.
CVE-2022-0902 1 Abb 14 Rmc-100, Rmc-100-lite, Rmc-100-lite Firmware and 11 more 2024-11-21 N/A 8.1 HIGH
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
CVE-2022-0010 1 Abb 5 Platform Engineering Tools, Qcs 800xa, Qcs 800xa Firmware and 2 more 2024-11-21 N/A 7.8 HIGH
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.