Filtered by vendor Xerox
Subscribe
Total
103 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-1999-1343 | 1 Xerox | 1 Docucolor 4lp | 2024-11-20 | 5.0 MEDIUM | N/A |
HTTP server for Xerox DocuColor 4 LP allows remote attackers to cause a denial of service (hang) via a long URL that contains a large number of . characters. | |||||
CVE-2024-47559 | 1 Xerox | 1 Freeflow Core | 2024-10-16 | N/A | 8.8 HIGH |
Authenticated RCE via Path Traversal | |||||
CVE-2024-47558 | 1 Xerox | 1 Freeflow Core | 2024-10-16 | N/A | 8.8 HIGH |
Authenticated RCE via Path Traversal | |||||
CVE-2024-47556 | 1 Xerox | 1 Freeflow Core | 2024-10-16 | N/A | 9.8 CRITICAL |
Pre-Auth RCE via Path Traversal | |||||
CVE-2024-47557 | 1 Xerox | 1 Freeflow Core | 2024-10-16 | N/A | 9.8 CRITICAL |
Pre-Auth RCE via Path Traversal | |||||
CVE-2022-26572 | 1 Xerox | 2 Colorqube 8580, Colorqube 8580 Firmware | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
Xerox ColorQube 8580 was discovered to contain an access control issue which allows attackers to print, view the status, and obtain sensitive information. | |||||
CVE-2021-37354 | 1 Xerox | 2 Phaser 4622, Phaser 4622 Firmware | 2024-02-04 | 7.5 HIGH | 9.8 CRITICAL |
Xerox Phaser 4622 v35.013.01.000 was discovered to contain a buffer overflow in the function sub_3226AC via the TIMEZONE variable. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data. | |||||
CVE-2022-23968 | 1 Xerox | 21 Versalink B400, Versalink B405, Versalink B600 and 18 more | 2024-02-04 | 7.8 HIGH | 7.5 HIGH |
Xerox VersaLink devices on specific versions of firmware before 2022-01-26 allow remote attackers to brick the device via a crafted TIFF file in an unauthenticated HTTP POST request. There is a permanent denial of service because image parsing causes a reboot, but image parsing is restarted as soon as the boot process finishes. However, this boot loop can be resolved by a field technician. The TIFF file must have an incomplete Image Directory. Affected firmware versions include xx.42.01 and xx.50.61. NOTE: the 2022-01-24 NeoSmart article included "believed to affect all previous and later versions as of the date of this posting" but a 2022-01-26 vendor statement reports "the latest versions of firmware are not vulnerable to this issue." | |||||
CVE-2022-23320 | 1 Xerox | 1 Xmpie Ustore | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
XMPie uStore 12.3.7244.0 allows for administrators to generate reports based on raw SQL queries. Since the application ships with default administrative credentials, an attacker may authenticate into the application and exfiltrate sensitive information from the database. | |||||
CVE-2019-10881 | 1 Xerox | 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more | 2024-02-04 | 7.5 HIGH | 9.8 CRITICAL |
Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled. | |||||
CVE-2021-28672 | 1 Xerox | 48 Phaser 6510, Phaser 6510 Firmware, Versalink B400 and 45 more | 2024-02-04 | 7.5 HIGH | 9.8 CRITICAL |
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 allows remote attackers to execute arbitrary code through a buffer overflow in Web page parameter handling. | |||||
CVE-2021-28668 | 1 Xerox | 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more | 2024-02-04 | 7.5 HIGH | 9.8 CRITICAL |
Xerox AltaLink B80xx before 103.008.020.23120, C8030/C8035 before 103.001.020.23120, C8045/C8055 before 103.002.020.23120 and C8070 before 103.003.020.23120 has several SQL injection vulnerabilities. | |||||
CVE-2021-28670 | 1 Xerox | 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more | 2024-02-04 | 6.4 MEDIUM | 9.1 CRITICAL |
Xerox AltaLink B8045/B8090 before 103.008.030.32000, C8030/C8035 before 103.001.030.32000, C8045/C8055 before 103.002.030.32000 and C8070 before 103.003.030.32000 allow unauthorized users, by leveraging the Scan To Mailbox feature, to delete arbitrary files from the disk. | |||||
CVE-2021-28671 | 1 Xerox | 48 Phaser 6510, Phaser 6510 Firmware, Versalink B400 and 45 more | 2024-02-04 | 7.5 HIGH | 9.8 CRITICAL |
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 have a remote Command Execution vulnerability in the Web User Interface that allows remote attackers with "a weaponized clone file" to execute arbitrary commands. | |||||
CVE-2021-28669 | 1 Xerox | 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
Xerox AltaLink B80xx before 103.008.020.23120, C8030/C8035 before 103.001.020.23120, C8045/C8055 before 103.002.020.23120 and C8070 before 103.003.020.23120 provide the ability to set configuration attributes without administrative rights. | |||||
CVE-2021-28673 | 1 Xerox | 46 Phaser 6510, Phaser 6510 Firmware, Versalink B400 and 43 more | 2024-02-04 | 7.5 HIGH | 9.8 CRITICAL |
Xerox Phaser 6510 before 64.61.23 and 64.59.11 (Bridge), WorkCentre 6515 before 65.61.23 and 65.59.11 (Bridge), VersaLink B400 before 37.61.23 and 37.59.01 (Bridge), B405 before 38.61.23 and 38.59.01 (Bridge), B600/B610 before 32.61.23 and 32.59.01 (Bridge), B605/B615 before 33.61.23 and 33.59.01 (Bridge), B7025/30/35 before 58.61.23 and 58.59.11 (Bridge), C400 before 67.61.23 and 67.59.01 (Bridge), C405 before 68.61.23 and 68.59.01 (Bridge), C500/C600 before 61.61.23 and 61.59.01 (Bridge), C505/C605 before 62.61.23 and 62.59.11 (Bridge), C7000 before 56.61.23 and 56.59.01 (Bridge), C7020/25/30 before 57.61.23 and 57.59.01 (Bridge), C8000/C9000 before 70.61.23 and 70.59.01 (Bridge), allows remote attackers with "a weaponized clone file" to execute arbitrary commands in the Web User Interface. | |||||
CVE-2019-18629 | 1 Xerox | 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more | 2024-02-04 | 6.8 MEDIUM | 8.1 HIGH |
Xerox AltaLink B8045/B8055/B8065/B8075/B8090 and C8030/C8035/C8045/C8055/C8070 multifunction printers with software releases before 101.00x.099.28200 allow an attacker to execute an unwanted binary during a exploited clone install. This requires creating a clone file and signing that file with a compromised private key. | |||||
CVE-2019-18628 | 1 Xerox | 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more | 2024-02-04 | 4.0 MEDIUM | 4.9 MEDIUM |
Xerox AltaLink B8045/B8055/B8065/B8075/B8090 and C8030/C8035/C8045/C8055/C8070 multifunction printers with software releases before 101.00x.099.28200 allow a user with administrative privileges to turn off data encryption on the device, thus leaving it open to potential cryptographic information disclosure. | |||||
CVE-2019-18630 | 1 Xerox | 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
On Xerox AltaLink B8045/B8055/B8065/B8075/B8090 and C8030/C8035/C8045/C8055/C8070 multifunction printers with software releases before 101.00x.099.28200, portions of the drive containing executable code were not encrypted thus leaving it open to potential cryptographic information disclosure. | |||||
CVE-2020-36201 | 1 Xerox | 60 Workcentre 3655, Workcentre 3655 Firmware, Workcentre 3655i and 57 more | 2024-02-04 | 5.0 MEDIUM | 7.5 HIGH |
An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices. |