Vulnerabilities (CVE)

Filtered by vendor Rockwellautomation Subscribe
Total 300 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-7924 1 Rockwellautomation 8 1763-l16awa, 1763-l16awa Firmware, 1763-l16bbb and 5 more 2025-04-20 5.0 MEDIUM 7.5 HIGH
An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands (PCCC) packet to the controller that could potentially cause the controller to enter a DoS condition.
CVE-2017-7914 1 Rockwellautomation 2 Panelview Plus 6 700-1500, Panelview Plus 6 700-1500 Firmware 2025-04-20 7.5 HIGH 8.6 HIGH
A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access.
CVE-2017-5176 1 Rockwellautomation 8 9328-ccwdevdee, 9328-ccwdevene, 9328-ccwdevese and 5 more 2025-04-20 6.2 MEDIUM 7.0 HIGH
A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges.
CVE-2017-14022 1 Rockwellautomation 1 Factorytalk Alarms And Events 2025-04-20 5.0 MEDIUM 7.5 HIGH
An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.
CVE-2017-7898 1 Rockwellautomation 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more 2025-04-20 5.0 MEDIUM 9.8 CRITICAL
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords.
CVE-2024-11158 1 Rockwellautomation 1 Arena 2025-04-18 N/A 6.7 MEDIUM
An “uninitialized variable” code execution vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to craft a DOE file and force the software to access a variable before it being initialized. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor.
CVE-2020-14504 1 Rockwellautomation 4 1734-aentr Point I\/o Dual Port Network Adaptor Series B, 1734-aentr Point I\/o Dual Port Network Adaptor Series B Firmware, 1734-aentr Point I\/o Dual Port Network Adaptor Series C and 1 more 2025-04-17 5.0 MEDIUM 5.3 MEDIUM
The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings.
CVE-2020-14502 1 Rockwellautomation 4 1734-aentr Point I\/o Dual Port Network Adaptor Series B, 1734-aentr Point I\/o Dual Port Network Adaptor Series B Firmware, 1734-aentr Point I\/o Dual Port Network Adaptor Series C and 1 more 2025-04-17 4.3 MEDIUM 6.1 MEDIUM
The web interface of the 1734-AENTR communication module is vulnerable to stored XSS. A remote, unauthenticated attacker could store a malicious script within the web interface that, when executed, could modify some string values on the homepage of the web interface.
CVE-2020-14481 1 Rockwellautomation 1 Factorytalk View 2025-04-17 2.1 LOW 7.8 HIGH
The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE.
CVE-2020-14480 1 Rockwellautomation 1 Factorytalk View 2025-04-17 2.1 LOW 5.5 MEDIUM
Due to usernames/passwords being stored in plaintext in Random Access Memory (RAM), a local, authenticated attacker could gain access to certain credentials, including Windows Logon credentials.
CVE-2020-14478 1 Rockwellautomation 1 Factorytalk Services Platform 2025-04-17 5.6 MEDIUM 7.1 HIGH
A local, authenticated attacker could use an XML External Entity (XXE) attack to exploit weakly configured XML files to access local or remote content. A successful exploit could potentially cause a denial-of-service condition and allow the attacker to arbitrarily read any local file via system-level services.
CVE-2021-32960 1 Rockwellautomation 1 Factorytalk Services Platform 2025-04-17 6.0 MEDIUM 8.5 HIGH
Rockwell Automation FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed contains a vulnerability that may allow a remote, authenticated attacker to bypass FactoryTalk Security policies based on the computer name. If successfully exploited, this may allow an attacker to have the same privileges as if they were logged on to the client machine.
CVE-2020-6998 1 Rockwellautomation 18 Armor Compact Guardlogix 5370, Armor Compact Guardlogix 5370 Firmware, Compact Guardlogix 5370 and 15 more 2025-04-17 N/A 5.8 MEDIUM
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
CVE-2024-11155 1 Rockwellautomation 1 Arena 2025-04-14 N/A 7.8 HIGH
A “use after free” code execution vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to craft a DOE file and force the software to use a resource that was already used. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor.
CVE-2015-6492 1 Rockwellautomation 2 Micrologix 1100 Firmware, Micrologix 1400 Firmware 2025-04-12 7.8 HIGH N/A
Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote attackers to cause a denial of service (memory corruption and device crash) via a crafted HTTP request.
CVE-2014-5410 1 Rockwellautomation 1 Ab Micrologix Controller 2025-04-12 7.1 HIGH N/A
The DNP3 feature on Rockwell Automation Allen-Bradley MicroLogix 1400 1766-Lxxxxx A FRN controllers 7 and earlier and 1400 1766-Lxxxxx B FRN controllers before 15.001 allows remote attackers to cause a denial of service (process disruption) via malformed packets over (1) an Ethernet network or (2) a serial line.
CVE-2015-6490 1 Rockwellautomation 2 Micrologix 1100 Firmware, Micrologix 1400 Firmware 2025-04-12 10.0 HIGH N/A
Stack-based buffer overflow on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices through B FRN 15.003 allows remote attackers to execute arbitrary code via unspecified vectors.
CVE-2015-6491 1 Rockwellautomation 2 Micrologix 1100 Firmware, Micrologix 1400 Firmware 2025-04-12 4.0 MEDIUM N/A
Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticated users to insert the content of an arbitrary file into a FRAME element via unspecified vectors.
CVE-2016-0868 1 Rockwellautomation 9 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 6 more 2025-04-12 10.0 HIGH 9.8 CRITICAL
Stack-based buffer overflow on Rockwell Automation Allen-Bradley MicroLogix 1100 devices A through 15.000 and B before 15.002 allows remote attackers to execute arbitrary code via a crafted web request.
CVE-2016-2279 1 Rockwellautomation 46 Compactlogix 1756-en2f Series A, Compactlogix 1756-en2f Series A Firmware, Compactlogix 1756-en2f Series B and 43 more 2025-04-12 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in the web server in Rockwell Automation Allen-Bradley CompactLogix 1769-L* before 28.011+ allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.