Filtered by vendor Rockwellautomation
Subscribe
Total
296 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-14821 | 1 Rockwellautomation | 1 Rslinx | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality. | |||||
CVE-2018-10619 | 1 Rockwellautomation | 2 Factorytalk Linx Gateway, Rslinx Classic | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation. | |||||
CVE-2018-0163 | 2 Cisco, Rockwellautomation | 96 1120 Connected Grid Router, 1240 Connected Grid Router, 1905 Serial Integrated Services Router and 93 more | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
A vulnerability in the 802.1x multiple-authentication (multi-auth) feature of Cisco IOS Software could allow an unauthenticated, adjacent attacker to bypass the authentication phase on an 802.1x multi-auth port. The vulnerability is due to a logic change error introduced into the code. An attacker could exploit this vulnerability by trying to access an 802.1x multi-auth port after a successful supplicant has authenticated. An exploit could allow the attacker to bypass the 802.1x access controls and obtain access to the network. Cisco Bug IDs: CSCvg69701. | |||||
CVE-2017-9312 | 1 Rockwellautomation | 2 Allen-bradley L30erms, Allen-bradley L30erms Firmware | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
Improperly implemented option-field processing in the TCP/IP stack on Allen-Bradley L30ERMS safety devices v30 and earlier causes a denial of service. When a crafted TCP packet is received, the device reboots immediately. | |||||
CVE-2017-6015 | 1 Rockwellautomation | 1 Factorytalk Activation | 2024-11-21 | 7.2 HIGH | 7.8 HIGH |
Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later. | |||||
CVE-2017-16740 | 1 Rockwellautomation | 12 1766-l32awa, 1766-l32awa Firmware, 1766-l32awaa and 9 more | 2024-11-21 | 7.5 HIGH | 10.0 CRITICAL |
A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. | |||||
CVE-2017-14473 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 10.0 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Reads the encoded ladder logic from its data file and print it out in HEX. | |||||
CVE-2017-14472 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 10.0 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Requests a specific set of bytes from an undocumented data file and returns the ASCII version of the master password. | |||||
CVE-2017-14471 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 10.0 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Codes: 0023, 002e, and 0037 Fault Type: Recoverable Description: The STI, EII, and HSC function files contain bits signifying whether or not a fault has occurred. Additionally there is a bit signaling the module to auto start. When these bits are set for any of the three modules and the device is moved into a run state, a fault is triggered. | |||||
CVE-2017-14470 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 10.0 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix. | |||||
CVE-2017-14469 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 10.0 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0028 Fault Type: Non-User Description: Values 0x01 and 0x02 are invalid values for the user fault routine. By writing directly to the file it is possible to set these values. When this is done and the device is moved into a run state, a fault is triggered. NOTE: This is not possible through RSLogix. | |||||
CVE-2017-14468 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: This ability is leveraged in a larger exploit to flash custom firmware. | |||||
CVE-2017-14467 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Live rung edits are able to be made by an unauthenticated user allowing for addition, deletion, or modification of existing ladder logic. Additionally, faults and cpu state modification can be triggered if specific ladder logic is used. | |||||
CVE-2017-14466 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: The filetype 0x03 allows users write access, allowing the ability to overwrite the Master Password value stored in the file. | |||||
CVE-2017-14465 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Any input or output can be forced, causing unpredictable activity from the PLC. | |||||
CVE-2017-14464 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability.Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0001 Fault Type: Non-User Description: A fault state can be triggered by setting the NVRAM/memory module user program mismatch bit (S2:9) when a memory module is NOT installed. | |||||
CVE-2017-14463 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0012 Fault Type: Non-User Description: A fault state can be triggered by overwriting the ladder logic data file (type 0x22 number 0x02) with null values. | |||||
CVE-2017-14462 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG (also RUN for some) Description: Allows an attacker to enable SNMP, Modbus, DNP, and any other features in the channel configuration. Also allows attackers to change network parameters, such as IP address, name server, and domain name. | |||||
CVE-2017-12093 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
An exploitable insufficient resource pool vulnerability exists in the session communication functionality of Allen Bradley Micrologix 1400 Series B Firmware 21.2 and before. A specially crafted stream of packets can cause a flood of the session resource pool resulting in legitimate connections to the PLC being disconnected. An attacker can send unauthenticated packets to trigger this vulnerability. | |||||
CVE-2017-12092 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 5.0 MEDIUM | 3.7 LOW |
An exploitable file write vulnerability exists in the memory module functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a file write resulting in a new program being written to the memory module. An attacker can send an unauthenticated packet to trigger this vulnerability. |