Filtered by vendor Juniper
Subscribe
Total
885 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2016-1265 | 1 Juniper | 1 Junos Space | 2025-04-20 | 7.5 HIGH | 9.8 CRITICAL |
A remote unauthenticated network based attacker with access to Junos Space may execute arbitrary code on Junos Space or gain access to devices managed by Junos Space using cross site request forgery (CSRF), default authentication credentials, information leak and command injection attack vectors. All versions of Juniper Networks Junos Space prior to 15.1R3 are affected. | |||||
CVE-2017-10605 | 1 Juniper | 14 Junos, Srx100, Srx110 and 11 more | 2025-04-20 | 5.0 MEDIUM | 8.6 HIGH |
On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series. | |||||
CVE-2017-2315 | 1 Juniper | 1 Junos | 2025-04-20 | 7.8 HIGH | 7.5 HIGH |
On Juniper Networks EX Series Ethernet Switches running affected Junos OS versions, a vulnerability in IPv6 processing has been discovered that may allow a specially crafted IPv6 Neighbor Discovery (ND) packet destined to an EX Series Ethernet Switch to cause a slow memory leak. A malicious network-based packet flood of these crafted IPv6 NDP packets may eventually lead to resource exhaustion and a denial of service. The affected Junos OS versions are: 12.3 prior to 12.3R12-S4, 12.3R13; 13.3 prior to 13.3R10; 14.1 prior to 14.1R8-S3, 14.1R9; 14.1X53 prior ro 14.1X53-D12, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R6-S4, 14.2R7-S6, 14.2R8; 15.1 prior to 15.1R5; 16.1 before 16.1R3; 16.2 before 16.2R1-S3, 16.2R2. 17.1R1 and all subsequent releases have a resolution for this vulnerability. | |||||
CVE-2017-2330 | 1 Juniper | 1 Northstar Controller | 2025-04-20 | 4.9 MEDIUM | 6.2 MEDIUM |
A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unauthenticated, local user, to create a fork bomb scenario, also known as a rabbit virus, or wabbit, which will create processes that replicate themselves, until all resources are consumed on the system, leading to a denial of service to the entire system until it is restarted. Continued attacks by an unauthenticated, local user, can lead to persistent denials of services. | |||||
CVE-2016-1261 | 1 Juniper | 1 Junos | 2025-04-20 | 6.8 MEDIUM | 7.1 HIGH |
J-Web does not validate certain input that may lead to cross-site request forgery (CSRF) issues or cause a denial of J-Web service (DoS). | |||||
CVE-2017-2349 | 1 Juniper | 1 Junos | 2025-04-20 | 9.0 HIGH | 9.9 CRITICAL |
A command injection vulnerability in the IDP feature of Juniper Networks Junos OS on SRX series devices potentially allows a user with login access to the device to execute shell commands and elevate privileges. Affected releases are Juniper Networks Junos OS 12.1X44 prior to 12.1X44-D60; 12.1X46 prior to 12.1X46-D50; 12.1X47 prior to 12.1X47-D30, 12.1X47-D35; 12.3X48 prior to 12.3X48-D20, 12.3X48-D30; 15.1X49 prior to 15.1X49-D20, 15.1X49-D30. | |||||
CVE-2017-2300 | 1 Juniper | 1 Junos | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets. | |||||
CVE-2017-2302 | 1 Juniper | 1 Junos | 2025-04-20 | 7.8 HIGH | 7.5 HIGH |
On Juniper Networks products or platforms running Junos OS 12.1X46 prior to 12.1X46-D55, 12.1X47 prior to 12.1X47-D45, 12.3R13 prior to 12.3R13, 12.3X48 prior to 12.3X48-D35, 13.3 prior to 13.3R10, 14.1 prior to 14.1R8, 14.1X53 prior to 14.1X53-D40, 14.1X55 prior to 14.1X55-D35, 14.2 prior to 14.2R6, 15.1 prior to 15.1F2 or 15.1R1, 15.1X49 prior to 15.1X49-D20 where the BGP add-path feature is enabled with 'send' option or with both 'send' and 'receive' options, a network based attacker can cause the Junos OS rpd daemon to crash and restart. Repeated crashes of the rpd daemon can result in an extended denial of service condition. | |||||
CVE-2017-2306 | 1 Juniper | 1 Junos Space | 2025-04-20 | 6.5 MEDIUM | 8.8 HIGH |
On Juniper Networks Junos Space versions prior to 16.1R1, due to an insufficient authorization check, readonly users on the Junos Space administrative web interface can execute code on the device. | |||||
CVE-2017-2336 | 1 Juniper | 1 Screenos | 2025-04-20 | 3.5 LOW | 9.6 CRITICAL |
A reflected cross site scripting vulnerability in NetScreen WebUI of Juniper Networks Juniper NetScreen Firewall+VPN running ScreenOS allows a network based attacker to inject HTML/JavaScript content into the management session of other users including the administrator. This enables the attacker to effectively execute commands with the permissions of an administrator. This issue affects Juniper Networks ScreenOS 6.3.0 releases prior to 6.3.0r24 on SSG Series. No other Juniper Networks products or platforms are affected by this issue. | |||||
CVE-2016-4930 | 1 Juniper | 1 Junos Space | 2025-04-20 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in Junos Space before 15.2R2 allows remote attackers to steal sensitive information or perform certain administrative actions. | |||||
CVE-2017-10620 | 1 Juniper | 21 Junos, Srx100, Srx110 and 18 more | 2025-04-20 | 5.8 MEDIUM | 7.4 HIGH |
Juniper Networks Junos OS on SRX series devices do not verify the HTTPS server certificate before downloading anti-virus updates. This may allow a man-in-the-middle attacker to inject bogus signatures to cause service disruptions or make the device not detect certain types of attacks. Affected Junos OS releases are: 12.1X46 prior to 12.1X46-D71; 12.3X48 prior to 12.3X48-D55; 15.1X49 prior to 15.1X49-D110; | |||||
CVE-2017-2335 | 1 Juniper | 1 Screenos | 2025-04-20 | 3.5 LOW | 8.4 HIGH |
A persistent cross site scripting vulnerability in NetScreen WebUI of Juniper Networks Juniper NetScreen Firewall+VPN running ScreenOS allows a user with the 'security' role to inject HTML/JavaScript content into the management session of other users including the administrator. This enables the lower-privileged user to effectively execute commands with the permissions of an administrator. This issue affects Juniper Networks ScreenOS 6.3.0 releases prior to 6.3.0r24 on SSG Series. No other Juniper Networks products or platforms are affected by this issue. | |||||
CVE-2017-2318 | 1 Juniper | 1 Northstar Controller | 2025-04-20 | 4.0 MEDIUM | 6.5 MEDIUM |
A vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an authenticated malicious user to read log files which will compromise the integrity of the system, or provide elevation of privileges. | |||||
CVE-2017-10623 | 1 Juniper | 1 Junos Space | 2025-04-20 | 6.8 MEDIUM | 7.1 HIGH |
Lack of authentication and authorization of cluster messages in Juniper Networks Junos Space may allow a man-in-the-middle type of attacker to intercept, inject or disrupt Junos Space cluster operations between two nodes. Affected releases are Juniper Networks Junos Space all versions prior to 17.1R1. | |||||
CVE-2017-10613 | 1 Juniper | 1 Junos | 2025-04-20 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability in a specific loopback filter action command, processed in a specific logical order of operation, in a running configuration of Juniper Networks Junos OS, allows an attacker with CLI access and the ability to initiate remote sessions to the loopback interface with the defined action, to hang the kernel. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55; 12.3X48 prior to 12.3X48-D35; 14.1 prior to 14.1R8-S4, 14.1R9; 14.1X53 prior to 14.1X53-D40; 14.2 prior to 14.2R4-S9, 14.2R7-S8, 14.2R8; 15.1 prior to 15.1F5-S3, 15.1F6, 15.1R4; 15.1X49 prior to 15.1X49-D60; 15.1X53 prior to 15.1X53-D47; 16.1 prior to 16.1R2. No other Juniper Networks products or platforms are affected by this issue. | |||||
CVE-2017-2321 | 1 Juniper | 1 Northstar Controller | 2025-04-20 | 7.5 HIGH | 8.6 HIGH |
A vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unauthenticated, unprivileged, network-based attacker to cause various system services partial to full denials of services, modification of system states and files, and potential disclosure of sensitive information which may assist the attacker in further attacks on the system through the use of multiple attack vectors, including man-in-the-middle attacks, file injections, and malicious execution of commands causing out of bound memory conditions leading to other attacks. | |||||
CVE-2017-10617 | 1 Juniper | 1 Contrail | 2025-04-20 | 5.0 MEDIUM | 5.0 MEDIUM |
The ifmap service that comes bundled with Contrail has an XML External Entity (XXE) vulnerability that may allow an attacker to retrieve sensitive system files. Affected releases are Juniper Networks Contrail 2.2 prior to 2.21.4; 3.0 prior to 3.0.3.4; 3.1 prior to 3.1.4.0; 3.2 prior to 3.2.5.0. CVE-2017-10616 and CVE-2017-10617 can be chained together and have a combined CVSSv3 score of 5.8 (AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N). | |||||
CVE-2017-2341 | 1 Juniper | 13 Acx5000, Ex4600, Junos and 10 more | 2025-04-20 | 7.2 HIGH | 8.8 HIGH |
An insufficient authentication vulnerability on platforms where Junos OS instances are run in a virtualized environment, may allow unprivileged users on the Junos OS instance to gain access to the host operating environment, and thus escalate privileges. Affected releases are Juniper Networks Junos OS 14.1X53 prior to 14.1X53-D40 on QFX5110, QFX5200, QFX10002, QFX10008, QFX10016, EX4600 and NFX250; 15.1 prior to 15.1R5 on EX4600; 15.1X49 prior to 15.1X49-D70 on vSRX, SRX1500, SRX4100, SRX4200; 16.1 prior to 16.1R2 on EX4600, ACX5000 series. This issue does not affect vMX. No other Juniper Networks products or platforms are affected by this issue. | |||||
CVE-2017-2329 | 1 Juniper | 1 Northstar Controller | 2025-04-20 | 2.1 LOW | 6.2 MEDIUM |
An insufficient authentication vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unprivileged, authenticated, user to execute certain specific unprivileged system files capable of causing widespread denials of system services. |