Vulnerabilities (CVE)

Filtered by vendor Belden Subscribe
Total 30 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-12264 3 Belden, Siemens, Windriver 42 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 39 more 2024-02-04 4.8 MEDIUM 7.1 HIGH
Wind River VxWorks 6.6, 6.7, 6.8, 6.9.3, 6.9.4, and Vx7 has Incorrect Access Control in IPv4 assignment by the ipdhcpc DHCP client component.
CVE-2018-5471 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-02-04 4.3 MEDIUM 5.9 MEDIUM
A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A cleartext transmission of sensitive information vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.
CVE-2018-5461 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-02-04 5.8 MEDIUM 6.5 MEDIUM
An Inadequate Encryption Strength issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An inadequate encryption strength vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.
CVE-2018-5467 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-02-04 6.4 MEDIUM 6.5 MEDIUM
An Information Exposure Through Query Strings in GET Request issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An information exposure through query strings vulnerability in the web interface has been identified, which may allow an attacker to impersonate a legitimate user.
CVE-2018-5465 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-02-04 6.8 MEDIUM 8.8 HIGH
A Session Fixation issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A session fixation vulnerability in the web interface has been identified, which may allow an attacker to hijack web sessions.
CVE-2018-5469 1 Belden 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more 2024-02-04 7.5 HIGH 9.8 CRITICAL
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An improper restriction of excessive authentication vulnerability in the web interface has been identified, which may allow an attacker to brute force authentication.
CVE-2017-11400 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2024-02-04 7.2 HIGH 6.8 MEDIUM
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned.
CVE-2017-11402 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2024-02-04 10.0 HIGH 9.8 CRITICAL
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift.
CVE-2017-11401 1 Belden 2 Tofino Xenon Security Appliance, Tofino Xenon Security Appliance Firmware 2024-02-04 7.5 HIGH 9.8 CRITICAL
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Improper handling of the mbap.length field of ModBus packets in the ModBus DPI filter allows an attacker to send malformed/crafted packets to a protected asset, bypassing function code filtering.
CVE-2016-2509 1 Belden 6 Hirschmann Firmware, Hirschmann L2b, Hirschmann L2e and 3 more 2024-02-04 2.9 LOW 5.3 MEDIUM
The password-sync feature on Belden Hirschmann Classic Platform switches L2B before 05.3.07 and L2E, L2P, L3E, and L3P before 09.0.06 sets an SNMP community to the same string as the administrator password, which allows remote attackers to obtain sensitive information by sniffing the network.