Vulnerabilities (CVE)

Filtered by CWE-798
Total 1109 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-6387 1 Iball 2 Ib-wra150n, Ib-wra150n Firmware 2024-02-04 10.0 HIGH 9.8 CRITICAL
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
CVE-2018-0141 1 Cisco 3 Prime Collaboration, Prime Collaboration Assurance, Prime Collaboration Provisioning 2024-02-04 7.2 HIGH 8.4 HIGH
A vulnerability in Cisco Prime Collaboration Provisioning (PCP) Software 11.6 could allow an unauthenticated, local attacker to log in to the underlying Linux operating system. The vulnerability is due to a hard-coded account password on the system. An attacker could exploit this vulnerability by connecting to the affected system via Secure Shell (SSH) using the hard-coded credentials. A successful exploit could allow the attacker to access the underlying operating system as a low-privileged user. After low-level privileges are gained, the attacker could elevate to root privileges and take full control of the device. Cisco Bug IDs: CSCvc82982.
CVE-2016-9335 1 Redlion 4 Sixnet-managed Industrial Switches, Sixnet-managed Industrial Switches Firmware, Stride-managed Ethernet Switches and 1 more 2024-02-04 10.0 HIGH 10.0 CRITICAL
A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed Industrial switches use hard-coded HTTP SSL/SSH keys for secure communication. Because these keys cannot be regenerated by users, all products use the same key. The attacker could disrupt communication or compromise the system. CVSS v3 base score: 10, CVSS vector string: (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Red Lion Controls recommends updating to SLX firmware Version 5.3.174.
CVE-2017-3762 2 Lenovo, Microsoft 4 Fingerprint Manager Pro, Windows 7, Windows 8 and 1 more 2024-02-04 7.2 HIGH 7.8 HIGH
Sensitive data stored by Lenovo Fingerprint Manager Pro, version 8.01.86 and earlier, including users' Windows logon credentials and fingerprint data, is encrypted using a weak algorithm, contains a hard-coded password, and is accessible to all users with local non-administrative access to the system in which it is installed.
CVE-2018-10328 1 Momentum 2 Momentum Axel 720p, Momentum Axel 720p Firmware 2024-02-04 3.3 LOW 7.4 HIGH
Momentum Axel 720P 5.1.8 devices have a hardcoded password of streaming for the appagent account, which allows remote attackers to view the RTSP video stream.
CVE-2016-8717 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2024-02-04 10.0 HIGH 9.8 CRITICAL
An exploitable Use of Hard-coded Credentials vulnerability exists in the Moxa AWK-3131A Wireless Access Point running firmware 1.1. The device operating system contains an undocumented, privileged (root) account with hard-coded credentials, giving attackers full control of affected devices.
CVE-2018-11094 1 Intelbras 2 Ncloud 300, Ncloud 300 Firmware 2024-02-04 10.0 HIGH 9.8 CRITICAL
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.
CVE-2017-11634 1 - 1 Wireless Ip Camera 360 2024-02-04 10.0 HIGH 9.8 CRITICAL
An issue was discovered on Wireless IP Camera 360 devices. Remote attackers can discover a weakly encoded admin password by connecting to TCP port 9527 and reading the password field of the debugging information, e.g., nTBCS19C corresponds to a password of 123456.
CVE-2018-7047 1 Wowza 1 Streaming Engine 2024-02-04 7.5 HIGH 9.8 CRITICAL
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
CVE-2015-9254 1 Datto 16 Alto 2, Alto 2 Firmware, Alto 3 and 13 more 2024-02-04 7.5 HIGH 9.8 CRITICAL
Datto ALTO and SIRIS devices have a default VNC password.
CVE-2017-12725 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-02-04 6.8 MEDIUM 5.6 MEDIUM
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.
CVE-2017-17540 1 Fortinet 1 Fortiwlc 2024-02-04 10.0 HIGH 9.8 CRITICAL
The presence of a hardcoded account in Fortinet FortiWLC 8.3.3 allows attackers to gain unauthorized read/write access via a remote shell.
CVE-2018-4846 1 Siemens 6 Rapidlab 1200, Rapidlab 1200 Firmware, Rapidpoint 400 and 3 more 2024-02-04 10.0 HIGH 9.8 CRITICAL
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
CVE-2017-8013 1 Emc 1 Data Protection Advisor 2024-02-04 7.5 HIGH 9.8 CRITICAL
EMC Data Protection Advisor 6.3.x before patch 67 and 6.4.x before patch 130 contains undocumented accounts with hard-coded passwords and various privileges. Affected accounts are: "Apollo System Test", "emc.dpa.agent.logon" and "emc.dpa.metrics.logon". An attacker with knowledge of the password could potentially use these accounts via REST APIs to gain unauthorized access to EMC Data Protection Advisor (including potentially access with administrative privileges).
CVE-2018-1214 2 Dell, Microsoft 2 Emc Supportassist Enterprise, Windows 2024-02-04 4.4 MEDIUM 7.0 HIGH
Dell EMC SupportAssist Enterprise version 1.1 creates a local Windows user account named "OMEAdapterUser" with a default password as part of the installation process. This unnecessary user account also remains even after an upgrade from v1.1 to v1.2. Access to the management console can be achieved by someone with knowledge of the default password. If SupportAssist Enterprise is installed on a server running OpenManage Essentials (OME), the OmeAdapterUser user account is added as a member of the OmeAdministrators group for the OME. An unauthorized person with knowledge of the default password and access to the OME web console could potentially use this account to gain access to the affected installation of OME with OmeAdministrators privileges. This is fixed in version 1.2.1.
CVE-2017-12724 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2024-02-04 6.8 MEDIUM 8.1 HIGH
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections.
CVE-2018-6210 1 Dlink 2 Dir-620, Dir-620 Firmware 2024-02-04 10.0 HIGH 9.8 CRITICAL
D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
CVE-2018-0150 1 Cisco 3 4431 Integrated Services Router, 4451 Integrated Services Router, Ios Xe 2024-02-04 10.0 HIGH 9.8 CRITICAL
A vulnerability in Cisco IOS XE Software could allow an unauthenticated, remote attacker to log in to a device running an affected release of Cisco IOS XE Software with the default username and password that are used at initial boot, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with privilege level 15 that has a default username and password. An attacker could exploit this vulnerability by using this account to remotely connect to an affected device. A successful exploit could allow the attacker to log in to the device with privilege level 15 access. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS XE Software Release 16.x. This vulnerability does not affect Cisco IOS XE Software releases prior to Release 16.x. Cisco Bug IDs: CSCve89880.
CVE-2018-10813 1 Aprendecondedos 1 Dedos-web 2024-02-04 7.5 HIGH 7.3 HIGH
In Dedos-web 1.0, the cookie and session secrets used in the Express.js application have hardcoded values that are visible in the source code published on GitHub. An attacker can edit the contents of the session cookie and re-sign it using the hardcoded secret. Due to the use of Passport.js, this could lead to privilege escalation.
CVE-2018-0222 1 Cisco 1 Digital Network Architecture Center 2024-02-04 10.0 HIGH 10.0 CRITICAL
A vulnerability in Cisco Digital Network Architecture (DNA) Center could allow an unauthenticated, remote attacker to log in to an affected system by using an administrative account that has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the default administrative account for the affected software. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands with root privileges. This vulnerability affects all releases of Cisco DNA Center Software prior to Release 1.1.3. Cisco Bug IDs: CSCvh98929.