Total
13298 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-9007 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2025-09-26 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function formeditFileName of the file /goform/editFileName. The manipulation leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-9006 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2025-09-26 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was identified in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function formdelFileName of the file /goform/delFileName. The manipulation leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-10779 | 1 Dlink | 2 Dcs-935l, Dcs-935l Firmware | 2025-09-25 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in D-Link DCS-935L up to 1.13.01. The impacted element is the function sub_402280 of the file /HNAP1/. The manipulation of the argument HNAP_AUTH/SOAPAction results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer. | |||||
| CVE-2014-0789 | 1 Schneider-electric | 5 Opc Factory Server Tlxcdlfofs, Opc Factory Server Tlxcdltofs, Opc Factory Server Tlxcdluofs and 2 more | 2025-09-25 | 5.0 MEDIUM | N/A |
| Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions. | |||||
| CVE-2014-0787 | 1 Wellintech | 1 Kingscada | 2025-09-25 | 10.0 HIGH | N/A |
| Stack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet. | |||||
| CVE-2014-0784 | 1 Yokogawa | 1 Centum Cs 3000 | 2025-09-25 | 8.3 HIGH | N/A |
| Stack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet. | |||||
| CVE-2014-0783 | 1 Yokogawa | 1 Centum Cs 3000 | 2025-09-25 | 9.0 HIGH | N/A |
| Stack-based buffer overflow in BKHOdeq.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet. | |||||
| CVE-2014-0782 | 1 Yokogawa | 15 B\/m9000 Vp, B\/m9000 Vp Software, B\/m9000cs and 12 more | 2025-09-25 | 8.3 HIGH | N/A |
| Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and earlier, B/M9000CS R5.05.01 and earlier, and B/M9000 VP R7.03.01 and earlier allows remote attackers to execute arbitrary code via a crafted packet. | |||||
| CVE-2014-0781 | 1 Yokogawa | 1 Centum Cs 3000 | 2025-09-25 | 9.3 HIGH | N/A |
| Heap-based buffer overflow in BKCLogSvr.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via crafted UDP packets. | |||||
| CVE-2025-10815 | 1 Tenda | 2 Ac20, Ac20 Firmware | 2025-09-25 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was identified in Tenda AC20 up to 16.03.08.12. Affected by this issue is the function strcpy of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used. | |||||
| CVE-2014-0779 | 1 Aveva | 1 Clearscada | 2025-09-24 | 6.8 MEDIUM | N/A |
| The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build 73.4903, 2013 R1.2 build 73.4955, and 2013 R2 build 74.5094 allows remote attackers to cause a denial of service (application crash) via a crafted OPF file (aka project file). | |||||
| CVE-2014-0777 | 1 Ioserver | 2 Ioserver Opc Server, Opc Drivers | 2025-09-24 | 8.3 HIGH | N/A |
| The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service (out-of-bounds read and daemon crash) via a crafted packet. | |||||
| CVE-2014-0774 | 1 Schneider-electric | 6 Ofs Test Client Tlxcdlfofs33, Ofs Test Client Tlxcdltofs33, Ofs Test Client Tlxcdluofs33 and 3 more | 2025-09-24 | 6.8 MEDIUM | N/A |
| Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file. | |||||
| CVE-2025-10803 | 1 Tenda | 2 Ac23, Ac23 Firmware | 2025-09-24 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-10824 | 2025-09-24 | 4.3 MEDIUM | 5.3 MEDIUM | ||
| A vulnerability was determined in axboe fio up to 3.41. This impacts the function __parse_jobs_ini of the file init.c. Executing manipulation can lead to use after free. The attack needs to be launched locally. The exploit has been publicly disclosed and may be utilized. | |||||
| CVE-2025-21483 | 2025-09-24 | N/A | 9.8 CRITICAL | ||
| Memory corruption when the UE receives an RTP packet from the network, during the reassembly of NALUs. | |||||
| CVE-2025-9390 | 1 Vim | 1 Vim | 2025-09-24 | 4.3 MEDIUM | 5.3 MEDIUM |
| A security flaw has been discovered in vim up to 9.1.1615. Affected by this vulnerability is the function main of the file src/xxd/xxd.c of the component xxd. The manipulation results in buffer overflow. The attack requires a local approach. The exploit has been released to the public and may be exploited. Upgrading to version 9.1.1616 addresses this issue. The patch is identified as eeef7c77436a78cd27047b0f5fa6925d56de3cb0. It is recommended to upgrade the affected component. | |||||
| CVE-2025-23397 | 1 Siemens | 2 Teamcenter Visualization, Tecnomatix Plant Simulation | 2025-09-23 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2025-23398 | 1 Siemens | 2 Teamcenter Visualization, Tecnomatix Plant Simulation | 2025-09-23 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2025-23400 | 1 Siemens | 2 Teamcenter Visualization, Tecnomatix Plant Simulation | 2025-09-23 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. | |||||