Filtered by vendor Tenda
Subscribe
Total
627 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2025-5609 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5608 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5607 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-46035 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2025-06-17 | N/A | 7.5 HIGH |
Buffer Overflow vulnerability in Tenda AC6 v.15.03.05.16 allows a remote attacker to cause a denial of service via the oversized schedStartTime and schedEndTime parameters in an unauthenticated HTTP GET request to the /goform/openSchedWifi endpoint | |||||
CVE-2025-6111 | 1 Tenda | 2 Fh1205, Fh1205 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-6110 | 1 Tenda | 2 Fh1201, Fh1201 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda FH1201 1.2.0.14(408). This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-6113 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. Affected is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2023-49427 | 1 Tenda | 2 Ax12, Ax12 Firmware | 2025-06-16 | N/A | 7.5 HIGH |
Buffer Overflow vulnerability in Tenda AX12 V22.03.01.46, allows remote attackers to cause a denial of service (DoS) via list parameter in SetNetControlList function. | |||||
CVE-2025-5685 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2025-06-10 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda CH22 1.0.0.1. This affects the function formNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5794 | 1 Tenda | 2 Ac5, Ac5 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5795 | 1 Tenda | 2 Ac5, Ac5 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5798 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC8 16.03.34.09. It has been classified as critical. Affected is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeType leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5799 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5839 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5847 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5848 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC15 15.03.05.19_multi and classified as critical. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5849 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been classified as critical. This affects the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5850 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been declared as critical. This vulnerability affects the function formsetschedled of the file /goform/SetLEDCf of the component HTTP POST Request Handler. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5851 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been rated as critical. This issue affects the function fromadvsetlanip of the file /goform/AdvSetLanip of the component HTTP POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-5852 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2025-06-09 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. |