Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 626 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-52364 1 Tenda 2 Cp3 Pro, Cp3 Pro Firmware 2025-08-07 N/A 7.5 HIGH
Insecure Permissions vulnerability in Tenda CP3 Pro Firmware V22.5.4.93 allows the telnet service (telnetd) by default at boot via the initialization script /etc/init.d/eth.sh. This allows remote attackers to connect to the device s shell over the network, potentially without authentication if default or weak credentials are present
CVE-2025-8131 1 Tenda 2 Ac20, Ac20 Firmware 2025-08-05 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC20 16.03.08.05. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-8160 1 Tenda 2 Ac20, Ac20 Firmware 2025-08-05 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC20 up to 16.03.08.12. Affected is an unknown function of the file /goform/SetSysTimeCfg of the component httpd. The manipulation of the argument timeZone leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-8180 1 Tenda 2 Ch22, Ch22 Firmware 2025-08-05 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function formdeleteUserName of the file /goform/deleteUserName. The manipulation of the argument old_account leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-8017 1 Tenda 2 Ac7, Ac7 Firmware 2025-08-01 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-8060 1 Tenda 2 Ac23, Ac23 Firmware 2025-08-01 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC23 16.03.07.52 and classified as critical. Affected by this vulnerability is the function sub_46C940 of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-8178 1 Tenda 2 Ac10, Ac10 Firmware 2025-08-01 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-29360 1 Tenda 2 Rx3, Rx3 Firmware 2025-08-01 N/A 7.5 HIGH
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the time and timeZone parameters at /goform/SetSysTimeCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29359 1 Tenda 2 Rx3, Rx3 Firmware 2025-08-01 N/A 7.5 HIGH
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29358 1 Tenda 2 Rx3, Rx3 Firmware 2025-08-01 N/A 7.5 HIGH
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the firewallEn parameter at /goform/SetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-29357 1 Tenda 2 Rx3, Rx3 Firmware 2025-08-01 N/A 7.5 HIGH
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the startIp and endIp parameters at /goform/SetPptpServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
CVE-2025-3820 1 Tenda 4 I24, I24 Firmware, W12 and 1 more 2025-07-30 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644) and classified as critical. Affected by this issue is the function cgiSysUplinkCheckSet of the file /bin/httpd. The manipulation of the argument hostIp1/hostIp2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-3802 1 Tenda 4 I24, I24 Firmware, W12 and 1 more 2025-07-30 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been declared as critical. This vulnerability affects the function cgiPingSet of the file /bin/httpd. The manipulation of the argument pingIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-3803 1 Tenda 4 I24, I24 Firmware, W12 and 1 more 2025-07-30 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been rated as critical. This issue affects the function cgiSysScheduleRebootSet of the file /bin/httpd. The manipulation of the argument rebootDate leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-4007 1 Tenda 4 I24, I24 Firmware, W12 and 1 more 2025-07-30 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). Affected by this vulnerability is the function cgidhcpsCfgSet of the file /goform/modules of the component httpd. The manipulation of the argument json leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-51087 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 8.6 HIGH
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.
CVE-2025-7807 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. This issue affects the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7806 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. This vulnerability affects the function fromSafeClientFilter of the file /goform/SafeClientFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7805 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7796 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-23 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.