CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-30591 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-03-13 N/A 8.8 HIGH
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function.
CVE-2024-30583 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-03-13 N/A 8.0 HIGH
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the mitInterface parameter of the fromAddressNat function.
CVE-2024-2546 1 Tenda 2 Ac18, Ac18 Firmware 2025-03-11 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-25235 1 Tenda 2 Ac500, Ac500 Firmware 2025-03-10 N/A 7.5 HIGH
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid.
CVE-2023-27065 1 Tenda 2 W15e, W15e Firmware 2025-02-27 N/A 7.5 HIGH
Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the picName parameter in the formDelWewifiPi function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2023-27064 1 Tenda 2 W15e, W15e Firmware 2025-02-27 N/A 7.5 HIGH
Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the index parameter in the formDelDnsForward function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2023-27062 1 Tenda 2 W15e, W15e Firmware 2025-02-27 N/A 7.5 HIGH
Tenda V15V1.0 was discovered to contain a buffer overflow vulnerability via the gotoUrl parameter in the formPortalAuth function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2023-27079 1 Tenda 2 G103, G103 Firmware 2025-02-25 N/A 7.5 HIGH
Command Injection vulnerability found in Tenda G103 v.1.0.05 allows an attacker to obtain sensitive information via a crafted package
CVE-2023-27042 1 Tenda 2 Ax3, Ax3 Firmware 2025-02-20 N/A 8.8 HIGH
Tenda AX3 V16.03.12.11 is vulnerable to Buffer Overflow via /goform/SetFirewallCfg.
CVE-2024-0532 1 Tenda 2 A15, A15 Firmware 2025-02-16 8.3 HIGH 7.2 HIGH
A vulnerability was found in Tenda A15 15.13.07.13. It has been declared as critical. This vulnerability affects the function set_repeat5 of the file /goform/WifiExtraSet of the component Web-based Management Interface. The manipulation of the argument wpapsk_crypto2_4g/wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-26976 1 Tenda 2 Ac6, Ac6 Firmware 2025-02-13 N/A 7.5 HIGH
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2024-3909 1 Tenda 2 Ac500, Ac500 Firmware 2025-02-07 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-30356 1 Tenda 2 Cp3, Cp3 Firmware 2025-01-27 N/A 7.5 HIGH
Missing Support for an Integrity Check in Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 allows attackers to update the device with crafted firmware
CVE-2023-30351 1 Tenda 2 Cp3, Cp3 Firmware 2025-01-27 N/A 7.5 HIGH
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for root which is stored using weak encryption. This vulnerability allows attackers to connect to the TELNET service (or UART) by using the exposed credentials.
CVE-2024-4491 1 Tenda 2 I21, I21 Firmware 2025-01-27 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4492 1 Tenda 2 I21, I21 Firmware 2025-01-27 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4493 1 Tenda 2 I21, I21 Firmware 2025-01-27 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4494 1 Tenda 2 I21, I21 Firmware 2025-01-27 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4495 1 Tenda 2 I21, I21 Firmware 2025-01-27 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4496 1 Tenda 2 I21, I21 Firmware 2025-01-27 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.