Filtered by vendor Siemens
Subscribe
Total
208 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2016-5743 | 1 Siemens | 5 Simatic Batch, Simatic Openpcs 7, Simatic Pcs 7 and 2 more | 2025-04-12 | 10.0 HIGH | 9.8 CRITICAL |
Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets. | |||||
CVE-2016-9157 | 1 Siemens | 1 Sicam Pas | 2025-04-12 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to cause a Denial of Service condition and potentially lead to unauthenticated remote code execution by sending specially crafted packets to port 19234/TCP. | |||||
CVE-2022-22965 | 5 Cisco, Oracle, Siemens and 2 more | 39 Cx Cloud Agent, Commerce Platform, Communications Cloud Native Core Automated Test Suite and 36 more | 2025-04-10 | 7.5 HIGH | 9.8 CRITICAL |
A Spring MVC or Spring WebFlux application running on JDK 9+ may be vulnerable to remote code execution (RCE) via data binding. The specific exploit requires the application to run on Tomcat as a WAR deployment. If the application is deployed as a Spring Boot executable jar, i.e. the default, it is not vulnerable to the exploit. However, the nature of the vulnerability is more general, and there may be other ways to exploit it. | |||||
CVE-2019-0708 | 3 Huawei, Microsoft, Siemens | 131 Agile Controller-campus, Agile Controller-campus Firmware, Bh620 V2 and 128 more | 2025-04-07 | 10.0 HIGH | 9.8 CRITICAL |
A remote code execution vulnerability exists in Remote Desktop Services formerly known as Terminal Services when an unauthenticated attacker connects to the target system using RDP and sends specially crafted requests, aka 'Remote Desktop Services Remote Code Execution Vulnerability'. | |||||
CVE-2021-44228 | 12 Apache, Apple, Bentley and 9 more | 167 Log4j, Xcode, Synchro and 164 more | 2025-04-03 | 9.3 HIGH | 10.0 CRITICAL |
Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects. | |||||
CVE-2002-1484 | 1 Siemens | 1 Db4web | 2025-04-03 | 7.5 HIGH | 9.8 CRITICAL |
DB4Web server, when configured to use verbose debug messages, allows remote attackers to use DB4Web as a proxy and attempt TCP connections to other systems (port scan) via a request for a URL that specifies the target IP address and port, which produces a connection status in the resulting error message. | |||||
CVE-2021-45046 | 7 Apache, Cvat, Debian and 4 more | 61 Log4j, Computer Vision Annotation Tool, Debian Linux and 58 more | 2025-03-12 | 5.1 MEDIUM | 9.0 CRITICAL |
It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default. | |||||
CVE-2024-27939 | 1 Siemens | 1 Ruggedcom Crossbow | 2025-02-06 | N/A | 9.8 CRITICAL |
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow the upload of arbitrary files of any unauthenticated user. An attacker could leverage this vulnerability and achieve arbitrary code execution with system privileges. | |||||
CVE-2024-39872 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-11-21 | N/A | 9.6 CRITICAL |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the 'Manage firmware updates' role to escalate their privileges on the underlying OS level. | |||||
CVE-2024-23816 | 1 Siemens | 1 Location Intelligence | 2024-11-21 | N/A | 9.8 CRITICAL |
A vulnerability has been identified in Location Intelligence Perpetual Large (9DE5110-8CA13-1AX0) (All versions < V4.3), Location Intelligence Perpetual Medium (9DE5110-8CA12-1AX0) (All versions < V4.3), Location Intelligence Perpetual Non-Prod (9DE5110-8CA10-1AX0) (All versions < V4.3), Location Intelligence Perpetual Small (9DE5110-8CA11-1AX0) (All versions < V4.3), Location Intelligence SUS Large (9DE5110-8CA13-1BX0) (All versions < V4.3), Location Intelligence SUS Medium (9DE5110-8CA12-1BX0) (All versions < V4.3), Location Intelligence SUS Non-Prod (9DE5110-8CA10-1BX0) (All versions < V4.3), Location Intelligence SUS Small (9DE5110-8CA11-1BX0) (All versions < V4.3). Affected products use a hard-coded secret value for the computation of a Keyed-Hash Message Authentication Code. This could allow an unauthenticated remote attacker to gain full administrative access to the application. | |||||
CVE-2024-22039 | 1 Siemens | 9 Cerberus Pro En Engineering Tool, Cerberus Pro En Fire Panel Fc72x, Cerberus Pro En X200 Cloud Distribution and 6 more | 2024-11-21 | N/A | 10.0 CRITICAL |
A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions < IP8), Cerberus PRO EN Fire Panel FC72x IP6 (All versions < IP6 SR3), Cerberus PRO EN Fire Panel FC72x IP7 (All versions < IP7 SR5), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions < V3.0.6602), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.0.5016), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions < V3.2.6601), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.2.5015), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions < MP8), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions < MP6 SR3), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions < MP7 SR5), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions < V3.0.6602), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.0.5016), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions < V3.2.6601), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.2.5015), Sinteso Mobile (All versions < V3.0.0). The network communication library in affected systems does not validate the length of certain X.509 certificate attributes which might result in a stack-based buffer overflow. This could allow an unauthenticated remote attacker to execute code on the underlying operating system with root privileges. | |||||
CVE-2023-51438 | 2 Microchip, Siemens | 4 Maxview Storage Manager, Simatic Ipc1047e, Simatic Ipc647e and 1 more | 2024-11-21 | N/A | 10.0 CRITICAL |
A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access. | |||||
CVE-2023-49621 | 1 Siemens | 1 Simatic Cn 4100 | 2024-11-21 | N/A | 9.8 CRITICAL |
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device. | |||||
CVE-2023-46601 | 1 Siemens | 1 Comos | 2024-11-21 | N/A | 9.6 CRITICAL |
A vulnerability has been identified in COMOS (All versions). The affected application lacks proper access controls in making the SQLServer connection. This could allow an attacker to query the database directly to access information that the user should not have access to. | |||||
CVE-2023-44373 | 1 Siemens | 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more | 2024-11-21 | N/A | 9.1 CRITICAL |
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V2.4.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.4.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V2.4.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V2.4.0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions < V2.4.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V2.4.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions < V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V2.4.0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions < V2.4.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V2.4.0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions < V2.4.0). Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323. | |||||
CVE-2023-43625 | 1 Siemens | 1 Simcenter Amesim | 2024-11-21 | N/A | 9.8 CRITICAL |
A vulnerability has been identified in Simcenter Amesim (All versions < V2021.1). The affected application contains a SOAP endpoint that could allow an unauthenticated remote attacker to perform DLL injection and execute arbitrary code in the context of the affected application process. | |||||
CVE-2023-43505 | 1 Siemens | 1 Comos | 2024-11-21 | N/A | 9.6 CRITICAL |
A vulnerability has been identified in COMOS (All versions). The affected application lacks proper access controls in SMB shares. This could allow an attacker to access files that the user should not have access to. | |||||
CVE-2023-43504 | 1 Siemens | 1 Comos | 2024-11-21 | N/A | 9.6 CRITICAL |
A vulnerability has been identified in COMOS (All versions < V10.4.4). Ptmcast executable used for testing cache validation service in affected application is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition. | |||||
CVE-2023-37372 | 1 Siemens | 1 Ruggedcom Crossbow | 2024-11-21 | N/A | 9.8 CRITICAL |
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an unauthenticated remote attackers to execute arbitrary SQL queries on the server database. | |||||
CVE-2023-36755 | 1 Siemens | 22 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Mx5000re and 19 more | 2024-11-21 | N/A | 9.1 CRITICAL |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP CA Certificate Name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. |