Show plain JSON{"id": "CVE-2024-45464", "cveTags": [], "metrics": {"cvssMetricV31": [{"type": "Secondary", "source": "productcert@siemens.com", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}, {"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}], "cvssMetricV40": [{"type": "Secondary", "source": "productcert@siemens.com", "cvssData": {"safety": "NOT_DEFINED", "version": "4.0", "recovery": "NOT_DEFINED", "baseScore": 7.3, "automatable": "NOT_DEFINED", "attackVector": "LOCAL", "baseSeverity": "HIGH", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "userInteraction": "PASSIVE", "attackComplexity": "HIGH", "attackRequirements": "NONE", "privilegesRequired": "NONE", "modifiedAttackVector": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subsequentSystemIntegrity": "NONE", "vulnerableSystemIntegrity": "HIGH", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "vulnerableSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "NONE", "vulnerableSystemConfidentiality": "HIGH", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED"}}]}, "published": "2024-10-08T09:15:12.370", "references": [{"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html", "tags": ["Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html", "source": "productcert@siemens.com"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-125"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2302 (todas las versiones anteriores a V2302.0016) y Tecnomatix Plant Simulation V2404 (todas las versiones anteriores a V2404.0005). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras se analizan archivos WRL especialmente manipulados. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo en el contexto del proceso actual."}], "lastModified": "2024-12-10T14:30:41.117", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "00AE6AA5-618F-4494-B8D6-2AC25A5DC2F1", "versionEndExcluding": "2302.0016"}, {"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E84CE123-587E-480C-A6C8-AF7B4AE3ACF2", "versionEndExcluding": "2404.0005", "versionStartIncluding": "2303.0000"}], "operator": "OR"}]}], "sourceIdentifier": "productcert@siemens.com"}