CVE-2022-34465

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)
References
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*

History

13 Sep 2022, 10:15

Type Values Removed Values Added
Summary A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap (All versions). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420) A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)

10 Aug 2022, 12:15

Type Values Removed Values Added
Summary A vulnerability has been identified in Parasolid V33.1 (All versions), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap (All versions). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420) A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap (All versions). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)

20 Jul 2022, 15:29

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : 6.8
v3 : 7.8
CWE CWE-125
References (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf - (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf - Patch, Vendor Advisory
CPE cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*

12 Jul 2022, 10:15

Type Values Removed Values Added
New CVE

Information

Published : 2022-07-12 10:15

Updated : 2024-02-04 22:51


NVD link : CVE-2022-34465

Mitre link : CVE-2022-34465

CVE.ORG link : CVE-2022-34465


JSON object : View

Products Affected

siemens

  • simcenter_femap
  • parasolid
CWE
CWE-125

Out-of-bounds Read