Total
21 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-31158 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31151 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 4.2 MEDIUM |
An Improper Certificate Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31157 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31156 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31153 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31148 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 8.8 HIGH |
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-2310 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.3 MEDIUM |
A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service. See the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details. | |||||
CVE-2023-31166 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 4.3 MEDIUM |
An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31163 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31160 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31155 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31164 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31162 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 4.3 MEDIUM |
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31159 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31154 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31149 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 8.8 HIGH |
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31150 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 6.5 MEDIUM |
A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) database system could allow an authenticated attacker to retrieve passwords. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31165 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 5.4 MEDIUM |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2023-31152 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-02-04 | N/A | 8.8 HIGH |
An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
CVE-2013-2798 | 1 Selinc | 4 Sel-2241, Sel-3505, Sel-3530 and 1 more | 2024-02-04 | 4.7 MEDIUM | N/A |
Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |