Vulnerabilities (CVE)

Filtered by vendor Eurosoft Subscribe
Filtered by product Przychodnia
Total 1 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-1228 1 Eurosoft 1 Przychodnia 2024-06-12 N/A 9.8 CRITICAL
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software beforeĀ versionĀ 20240417.001 (from that version vulnerability is fixed).