Total
5 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2016-4527 | 1 Abb | 1 Pcm600 | 2024-11-21 | 1.9 LOW | 3.3 LOW |
ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors. | |||||
CVE-2016-4524 | 1 Abb | 1 Pcm600 | 2024-11-21 | 2.1 LOW | 6.5 MEDIUM |
ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors. | |||||
CVE-2016-4516 | 1 Abb | 1 Pcm600 | 2024-11-21 | 2.1 LOW | 3.3 LOW |
ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors. | |||||
CVE-2016-4511 | 1 Abb | 1 Pcm600 | 2024-11-21 | 1.9 LOW | 2.8 LOW |
ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file. | |||||
CVE-2022-2513 | 1 Abb | 12 Gms600, Gms600 Firmware, Pcm600 and 9 more | 2024-05-28 | N/A | 5.5 MEDIUM |
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs. |