Total
7 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-10750 | 1 Tenda | 2 I22, I22 Firmware | 2024-11-07 | 6.8 MEDIUM | 6.5 MEDIUM |
A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-7585 | 1 Tenda | 2 I22, I22 Firmware | 2024-09-11 | 9.0 HIGH | 9.8 CRITICAL |
A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-7584 | 1 Tenda | 2 I22, I22 Firmware | 2024-09-11 | 9.0 HIGH | 9.8 CRITICAL |
A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-7582 | 1 Tenda | 2 I22, I22 Firmware | 2024-08-08 | 9.0 HIGH | 9.8 CRITICAL |
A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-7583 | 1 Tenda | 2 I22, I22 Firmware | 2024-08-08 | 9.0 HIGH | 9.8 CRITICAL |
A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2022-45666 | 1 Tenda | 2 I22, I22 Firmware | 2024-02-04 | N/A | 7.5 HIGH |
Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the list parameter in the formwrlSSIDset function. | |||||
CVE-2022-45665 | 1 Tenda | 2 I22, I22 Firmware | 2024-02-04 | N/A | 7.5 HIGH |
Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the funcpara1 parameter in the formSetCfm function. |