CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-20918 | 1 Cisco | 2 Firepower Management Center, Firepower Services Software For Asa | 2024-02-04 | N/A | 7.5 HIGH |
A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential. This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential. This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed. | |||||
CVE-2022-20927 | 1 Cisco | 3 Adaptive Security Appliance Software, Firepower Services Software For Asa, Firepower Threat Defense | 2024-02-04 | N/A | 6.5 MEDIUM |
A vulnerability in the SSL/TLS client of Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. This vulnerability is due to improper memory management when a device initiates SSL/TLS connections. An attacker could exploit this vulnerability by ensuring that the device will connect to an SSL/TLS server that is using specific encryption parameters. A successful exploit could allow the attacker to cause the affected device to unexpectedly reload, resulting in a DoS condition. | |||||
CVE-2019-1981 | 1 Cisco | 3 Firepower Management Center, Firepower Services Software For Asa, Firepower Threat Defense | 2024-02-04 | 5.0 MEDIUM | 5.8 MEDIUM |
A vulnerability in the normalization functionality of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to insufficient normalization of a text-based payload. An attacker could exploit this vulnerability by sending traffic that contains specifically obfuscated payloads through an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious payloads to protected systems that would otherwise be blocked. | |||||
CVE-2019-1982 | 1 Cisco | 3 Firepower Management Center, Firepower Services Software For Asa, Firepower Threat Defense | 2024-02-04 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability in the HTTP traffic filtering component of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to improper handling of HTTP requests, including those communicated over a secure HTTPS connection, that contain maliciously crafted headers. An attacker could exploit this vulnerability by sending malicious requests to an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious requests to protected systems, allowing attackers to deliver malicious content that would otherwise be blocked. | |||||
CVE-2019-1978 | 1 Cisco | 3 Firepower Management Center, Firepower Services Software For Asa, Firepower Threat Defense | 2024-02-04 | 5.0 MEDIUM | 5.8 MEDIUM |
A vulnerability in the stream reassembly component of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to improper reassembly of traffic streams. An attacker could exploit this vulnerability by sending crafted streams through an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious requests to protected systems that would otherwise be blocked. | |||||
CVE-2019-1980 | 1 Cisco | 3 Firepower Management Center, Firepower Services Software For Asa, Firepower Threat Defense | 2024-02-04 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability in the protocol detection component of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to improper detection of the initial use of a protocol on a nonstandard port. An attacker could exploit this vulnerability by sending traffic on a nonstandard port for the protocol in use through an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious requests to protected systems that would otherwise be blocked. Once the initial protocol flow on the nonstandard port is detected, future flows on the nonstandard port will be successfully detected and handled as configured by the applied policy. |