Total
25 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2025-29101 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-25 | N/A | 7.5 HIGH |
Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function. | |||||
CVE-2025-25667 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info. | |||||
CVE-2025-25668 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function. | |||||
CVE-2025-25664 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function. | |||||
CVE-2025-25663 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. | |||||
CVE-2024-57704 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. | |||||
CVE-2024-46652 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function. | |||||
CVE-2024-57703 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. | |||||
CVE-2024-4064 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-4065 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-4066 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2023-33675 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function. | |||||
CVE-2023-33673 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | |||||
CVE-2023-33672 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 7.5 HIGH |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. | |||||
CVE-2023-33671 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function. | |||||
CVE-2023-33670 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function. | |||||
CVE-2023-33669 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function. | |||||
CVE-2024-11745 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2024-12-03 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2023-4744 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability. | |||||
CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. |