Total
37 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-10434 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-01 | 9.0 HIGH | 9.8 CRITICAL |
A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-9793 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-01 | 6.5 MEDIUM | 9.8 CRITICAL |
A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-10280 | 1 Tenda | 20 Ac10, Ac10 Firmware, Ac10u and 17 more | 2024-11-01 | 6.8 MEDIUM | 7.5 HIGH |
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2023-38936 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
CVE-2023-37716 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | |||||
CVE-2023-38935 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac1206 and 7 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. | |||||
CVE-2023-38931 | 1 Tenda | 16 Ac10, Ac10 Firmware, Ac1206 and 13 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. | |||||
CVE-2023-38933 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | |||||
CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | |||||
CVE-2023-37717 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient. | |||||
CVE-2023-37710 | 1 Tenda | 4 Ac10, Ac10 Firmware, Ac1206 and 1 more | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. | |||||
CVE-2023-37712 | 1 Tenda | 6 Ac1206, Ac1206 Firmware, F1202 and 3 more | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function. | |||||
CVE-2023-37711 | 1 Tenda | 4 Ac10, Ac10 Firmware, Ac1206 and 1 more | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function. | |||||
CVE-2022-42079 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-02-04 | N/A | 7.5 HIGH |
Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via the function formWifiBasicSet. | |||||
CVE-2022-37810 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. | |||||
CVE-2022-37806 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromDhcpListClient. | |||||
CVE-2022-37802 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromNatStaticSetting. | |||||
CVE-2022-37801 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand. | |||||
CVE-2022-37807 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function formSetClientState. | |||||
CVE-2022-37809 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the speed_dir parameter in the function formSetSpeedWan. |