Total
49 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-11248 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-19 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-11056 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-11061 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-13 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-10280 | 1 Tenda | 20 Ac10, Ac10 Firmware, Ac10u and 17 more | 2024-11-01 | 6.8 MEDIUM | 7.5 HIGH |
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2023-45481 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-01 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg. | |||||
CVE-2024-2856 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-05-17 | 9.0 HIGH | 9.8 CRITICAL |
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2023-45483 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time. | |||||
CVE-2023-45484 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic. | |||||
CVE-2023-45482 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info. | |||||
CVE-2023-45479 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098. | |||||
CVE-2023-45480 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878. | |||||
CVE-2023-38936 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
CVE-2023-37716 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | |||||
CVE-2023-38935 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac1206 and 7 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. | |||||
CVE-2023-38931 | 1 Tenda | 16 Ac10, Ac10 Firmware, Ac1206 and 13 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. | |||||
CVE-2023-38933 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | |||||
CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | |||||
CVE-2023-37717 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-02-05 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient. | |||||
CVE-2023-37710 | 1 Tenda | 4 Ac10, Ac10 Firmware, Ac1206 and 1 more | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. | |||||
CVE-2023-34567 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-02-04 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. |