Vulnerabilities (CVE)

Filtered by vendor Dell Subscribe
Total 1184 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-8012 1 Dell 4 Emc M\&r, Emc Storage Monitoring And Reporting, Emc Vipr Srm and 1 more 2025-04-20 5.8 MEDIUM 7.4 HIGH
In EMC ViPR SRM, Storage M&R, VNX M&R, and M&R (Watch4Net) for SAS Solution Packs, the Java Management Extensions (JMX) protocol used to communicate between components in the Alerting and/or Compliance components can be leveraged to create a denial of service (DoS) condition. Attackers with knowledge of JMX agent user credentials could potentially exploit this vulnerability to create arbitrary files on the affected system and create a DoS condition by leveraging inherent JMX protocol capabilities.
CVE-2017-8021 1 Dell 1 Elastic Cloud Storage 2025-04-20 10.0 HIGH 9.8 CRITICAL
EMC Elastic Cloud Storage (ECS) before 3.1 is affected by an undocumented account vulnerability that could potentially be leveraged by malicious users to compromise the affected system.
CVE-2016-9682 1 Dell 1 Sonicwall Secure Remote Access Server 2025-04-20 10.0 HIGH 9.8 CRITICAL
The SonicWall Secure Remote Access server (version 8.1.0.2-14sv) is vulnerable to two Remote Command Injection vulnerabilities in its web administrative interface. These vulnerabilities occur in the diagnostics CGI (/cgi-bin/diagnostics) component responsible for emailing out information about the state of the system. The application doesn't properly escape the information passed in the 'tsrDeleteRestartedFile' or 'currentTSREmailTo' variables before making a call to system(), allowing for remote command injection. Exploitation of this vulnerability yields shell access to the remote machine under the nobody user account.
CVE-2015-7274 1 Dell 2 Integrated Remote Access Controller 6, Integrated Remote Access Controller Firmware 2025-04-20 6.5 MEDIUM 8.8 HIGH
Dell Integrated Remote Access Controller (iDRAC) 6 before 2.80 allows remote attackers to execute arbitrary administrative HTTP commands.
CVE-2017-4981 1 Dell 1 Bsafe Cert-c 2025-04-20 5.0 MEDIUM 7.5 HIGH
EMC RSA BSAFE Cert-C before 2.9.0.5 contains a potential improper certificate processing vulnerability.
CVE-2016-8217 1 Dell 1 Bsafe Crypto-j 2025-04-20 4.3 MEDIUM 3.7 LOW
EMC RSA BSAFE Crypto-J versions prior to 6.2.2 has a PKCS#12 Timing Attack Vulnerability. A possible timing attack could be carried out by modifying a PKCS#12 file that has an integrity MAC for which the password is not known. An attacker could then feed the modified PKCS#12 file to the toolkit and guess the current MAC one byte at a time. This is possible because Crypto-J uses a non-constant-time method to compare the stored MAC with the calculated MAC. This vulnerability is similar to the issue described in CVE-2015-2601.
CVE-2017-14375 2 Dell, Emc 4 Emc Unisphere, Solutions Enabler, Vasa and 1 more 2025-04-20 10.0 HIGH 9.8 CRITICAL
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, and EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier) contain an authentication bypass vulnerability that may potentially be exploited by malicious users to compromise the affected system.
CVE-2017-10949 1 Dell 1 Storage Manager 2016 2025-04-20 5.0 MEDIUM 7.5 HIGH
Directory Traversal in Dell Storage Manager 2016 R2.1 causes Information Disclosure when the doGet method of the EmWebsiteServlet class doesn't properly validate user provided path before using it in file operations. Was ZDI-CAN-4459.
CVE-2017-14386 1 Dell 4 2335dn, 2335dn Firmware, 2355dn and 1 more 2025-04-20 4.3 MEDIUM 6.1 MEDIUM
The web user interface of Dell 2335dn and 2355dn Multifunction Laser Printers, firmware versions prior to V2.70.06.26 A13 and V2.70.45.34 A10 respectively, are affected by a cross-site scripting vulnerability. Attackers could potentially exploit this vulnerability to execute arbitrary HTML or JavaScript code in the user's browser session in the context of the affected website.
CVE-2017-8011 1 Dell 4 Emc M\&r, Emc Storage Monitoring And Reporting, Emc Vipr Srm and 1 more 2025-04-20 10.0 HIGH 9.8 CRITICAL
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
CVE-2017-8007 1 Dell 4 Emc M\&r, Emc Storage Monitoring And Reporting, Emc Vipr Srm and 1 more 2025-04-20 6.5 MEDIUM 8.8 HIGH
In EMC ViPR SRM, Storage M&R, VNX M&R, and M&R (Watch4Net) for SAS Solution Packs, the Webservice Gateway is affected by a directory traversal vulnerability. Attackers with knowledge of Webservice Gateway credentials could potentially exploit this vulnerability to access unauthorized information, and modify or delete data, by supplying specially crafted strings in input parameters of the web service call.
CVE-2017-4997 1 Dell 1 Emc Vasa Provider Virtual Appliance 2025-04-20 10.0 HIGH 9.8 CRITICAL
EMC VASA Provider Virtual Appliance versions 8.3.x and prior has an unauthenticated remote code execution vulnerability that could potentially be exploited by malicious users to compromise the affected system.
CVE-2016-8211 1 Dell 1 Emc Data Protection Advisor 2025-04-20 5.0 MEDIUM 7.5 HIGH
EMC Data Protection Advisor 6.1.x, EMC Data Protection Advisor 6.2, EMC Data Protection Advisor 6.2.1, EMC Data Protection Advisor 6.2.2, EMC Data Protection Advisor 6.2.3 prior to patch 446 has a path traversal vulnerability that may potentially be exploited by malicious users to compromise the affected system.
CVE-2015-7271 1 Dell 3 Integrated Remote Access Controller 7, Integrated Remote Access Controller 8, Integrated Remote Access Controller Firmware 2025-04-20 7.5 HIGH 9.8 CRITICAL
Dell Integrated Remote Access Controller (iDRAC) 7/8 before 2.21.21.21 has a format string issue in racadm getsystinfo.
CVE-2015-7272 1 Dell 4 Integrated Remote Access Controller 6, Integrated Remote Access Controller 7, Integrated Remote Access Controller 8 and 1 more 2025-04-20 7.5 HIGH 9.8 CRITICAL
Dell Integrated Remote Access Controller (iDRAC) 6 before 2.80 and 7/8 before 2.21.21.21 allows attackers to cause a denial of service (buffer overflow) or possibly have unspecified other impact via a long SSH username or input.
CVE-2015-4056 1 Dell 1 Vce Vision Intelligent Operations 2025-04-20 2.1 LOW 6.7 MEDIUM
The System Library in VCE Vision Intelligent Operations before 2.6.5 does not properly implement cryptography, which makes it easier for local users to discover credentials by leveraging administrative access.
CVE-2017-15361 35 Acer, Aopen, Asi and 32 more 126 C720 Chromebook, Chromebase, Chromebase 24 and 123 more 2025-04-20 4.3 MEDIUM 5.9 MEDIUM
The Infineon RSA library 1.02.013 in Infineon Trusted Platform Module (TPM) firmware, such as versions before 0000000000000422 - 4.34, before 000000000000062b - 6.43, and before 0000000000008521 - 133.33, mishandles RSA key generation, which makes it easier for attackers to defeat various cryptographic protection mechanisms via targeted attacks, aka ROCA. Examples of affected technologies include BitLocker with TPM 1.2, YubiKey 4 (before 4.3.5) PGP key generation, and the Cached User Data encryption feature in Chrome OS.
CVE-2015-7273 1 Dell 3 Integrated Remote Access Controller 7, Integrated Remote Access Controller 8, Integrated Remote Access Controller Firmware 2025-04-20 7.5 HIGH 9.8 CRITICAL
Dell Integrated Remote Access Controller (iDRAC) 7/8 before 2.21.21.21 has XXE.
CVE-2015-7275 1 Dell 4 Integrated Remote Access Controller 6, Integrated Remote Access Controller 7, Integrated Remote Access Controller 8 and 1 more 2025-04-20 4.3 MEDIUM 6.1 MEDIUM
Dell Integrated Remote Access Controller (iDRAC) 6 before 2.85 and 7/8 before 2.30.30.30 has XSS.
CVE-2016-8212 1 Dell 1 Bsafe Crypto-j 2025-04-20 5.0 MEDIUM 7.5 HIGH
An issue was discovered in EMC RSA BSAFE Crypto-J versions prior to 6.2.2. There is an Improper OCSP Validation Vulnerability. OCSP responses have two time values: thisUpdate and nextUpdate. These specify a validity period; however, both values are optional. Crypto-J treats the lack of a nextUpdate as indicating that the OCSP response is valid indefinitely instead of restricting its validity for a brief period surrounding the thisUpdate time. This vulnerability is similar to the issue described in CVE-2015-4748.