Total
504 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-3862 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 7.8 HIGH | 8.6 HIGH |
Multiple vulnerabilities in the EnergyWise module of Cisco IOS (12.2 and 15.0 through 15.6) and Cisco IOS XE (3.2 through 3.18) could allow an unauthenticated, remote attacker to cause a buffer overflow condition or a reload of an affected device, leading to a denial of service (DoS) condition. These vulnerabilities are due to improper parsing of crafted EnergyWise packets destined to an affected device. An attacker could exploit these vulnerabilities by sending crafted EnergyWise packets to be processed by an affected device. An exploit could allow the attacker to cause a buffer overflow condition or a reload of the affected device, leading to a DoS condition. Cisco IOS Software and Cisco IOS XE Software support EnergyWise for IPv4 communication. Only IPv4 packets destined to a device configured as an EnergyWise domain member can trigger these vulnerabilities. IPv6 packets cannot be used to trigger these vulnerabilities. Cisco Bug ID CSCuu76493. | |||||
CVE-2017-6738 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 9.0 HIGH | 8.8 HIGH |
The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve89865, CSCsy56638. | |||||
CVE-2017-3864 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 7.8 HIGH | 8.6 HIGH |
A vulnerability in the DHCP client implementation of Cisco IOS (12.2, 12.4, and 15.0 through 15.6) and Cisco IOS XE (3.3 through 3.7) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition. The vulnerability occurs during the parsing of a crafted DHCP packet. An attacker could exploit this vulnerability by sending crafted DHCP packets to an affected device that is configured as a DHCP client. A successful exploit could allow the attacker to cause a reload of an affected device, resulting in a DoS condition. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS or IOS XE Software and using a specific DHCP client configuration. Cisco Bug IDs: CSCuu43892. | |||||
CVE-2017-6739 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 9.0 HIGH | 8.8 HIGH |
The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve66540. | |||||
CVE-2017-6770 | 1 Cisco | 7 Adaptive Security Appliance Software, Ios, Ios Xe and 4 more | 2025-04-20 | 4.0 MEDIUM | 4.2 MEDIUM |
Cisco IOS 12.0 through 15.6, Adaptive Security Appliance (ASA) Software 7.0.1 through 9.7.1.2, NX-OS 4.0 through 12.0, and IOS XE 3.6 through 3.18 are affected by a vulnerability involving the Open Shortest Path First (OSPF) Routing Protocol Link State Advertisement (LSA) database. This vulnerability could allow an unauthenticated, remote attacker to take full control of the OSPF Autonomous System (AS) domain routing table, allowing the attacker to intercept or black-hole traffic. The attacker could exploit this vulnerability by injecting crafted OSPF packets. Successful exploitation could cause the targeted router to flush its routing table and propagate the crafted OSPF LSA type 1 update throughout the OSPF AS domain. To exploit this vulnerability, an attacker must accurately determine certain parameters within the LSA database on the target router. This vulnerability can only be triggered by sending crafted unicast or multicast OSPF LSA type 1 packets. No other LSA type packets can trigger this vulnerability. OSPFv3 is not affected by this vulnerability. Fabric Shortest Path First (FSPF) protocol is not affected by this vulnerability. Cisco Bug IDs: CSCva74756, CSCve47393, CSCve47401. | |||||
CVE-2017-3849 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 6.1 MEDIUM | 7.4 HIGH |
A vulnerability in the Autonomic Networking Infrastructure (ANI) registrar feature of Cisco IOS Software (possibly 15.2 through 15.6) and Cisco IOS XE Software (possibly 3.7 through 3.18, and 16) could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condition. The vulnerability is due to incomplete input validation on certain crafted packets. An attacker could exploit this vulnerability by sending a crafted autonomic network channel discovery packet to a device that has all the following characteristics: (1) running a Cisco IOS Software or Cisco IOS XE Software release that supports the ANI feature; (2) configured as an autonomic registrar; (3) has a whitelist configured. An exploit could allow the attacker to cause the affected device to reload. Note: Autonomic networking should be configured with a whitelist. Do not remove the whitelist as a workaround. Cisco Bug IDs: CSCvc42717. | |||||
CVE-2017-12211 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 6.3 MEDIUM | 5.3 MEDIUM |
A vulnerability in the IPv6 Simple Network Management Protocol (SNMP) code of Cisco IOS and Cisco IOS XE Software could allow an authenticated, remote attacker to cause high CPU usage or a reload of the device. The vulnerability is due to IPv6 sub block corruption. An attacker could exploit this vulnerability by polling the affected device IPv6 information. An exploit could allow the attacker to trigger high CPU usage or a reload of the device. Known Affected Releases: Denali-16.3.1. Cisco Bug IDs: CSCvb14640. | |||||
CVE-2017-6663 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 6.1 MEDIUM | 6.5 MEDIUM |
A vulnerability in the Autonomic Networking feature of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, adjacent attacker to cause autonomic nodes of an affected system to reload, resulting in a denial of service (DoS) condition. More Information: CSCvd88936. Known Affected Releases: Denali-16.2.1 Denali-16.3.1. | |||||
CVE-2017-3857 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 7.8 HIGH | 7.5 HIGH |
A vulnerability in the Layer 2 Tunneling Protocol (L2TP) parsing function of Cisco IOS (12.0 through 12.4 and 15.0 through 15.6) and Cisco IOS XE (3.1 through 3.18) could allow an unauthenticated, remote attacker to cause an affected device to reload. The vulnerability is due to insufficient validation of L2TP packets. An attacker could exploit this vulnerability by sending a crafted L2TP packet to an affected device. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a denial of service (DoS) condition. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS or Cisco IOS XE Software if the L2TP feature is enabled for the device and the device is configured as an L2TP Version 2 (L2TPv2) or L2TP Version 3 (L2TPv3) endpoint. By default, the L2TP feature is not enabled. Cisco Bug IDs: CSCuy82078. | |||||
CVE-2017-6736 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 9.0 HIGH | 8.8 HIGH |
The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve57697. | |||||
CVE-2017-12228 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 4.3 MEDIUM | 5.9 MEDIUM |
A vulnerability in the Cisco Network Plug and Play application of Cisco IOS 12.4 through 15.6 and Cisco IOS XE 3.3 through 16.4 could allow an unauthenticated, remote attacker to gain unauthorized access to sensitive data by using an invalid certificate. The vulnerability is due to insufficient certificate validation by the affected software. An attacker could exploit this vulnerability by supplying a crafted certificate to an affected device. A successful exploit could allow the attacker to conduct man-in-the-middle attacks to decrypt confidential information on user connections to the affected software. Cisco Bug IDs: CSCvc33171. | |||||
CVE-2017-6615 | 1 Cisco | 1 Ios Xe | 2025-04-20 | 6.3 MEDIUM | 6.3 MEDIUM |
A vulnerability in the Simple Network Management Protocol (SNMP) subsystem of Cisco IOS XE 3.16 could allow an authenticated, remote attacker to cause a denial of service (DoS) condition. The vulnerability is due to a race condition that could occur when the affected software processes an SNMP read request that contains certain criteria for a specific object ID (OID) and an active crypto session is disconnected on an affected device. An attacker who can authenticate to an affected device could trigger this vulnerability by issuing an SNMP request for a specific OID on the device. A successful exploit will cause the device to restart due to an attempt to access an invalid memory region. The attacker does not control how or when crypto sessions are disconnected on the device. Cisco Bug IDs: CSCvb94392. | |||||
CVE-2017-3856 | 1 Cisco | 1 Ios Xe | 2025-04-20 | 7.8 HIGH | 7.5 HIGH |
A vulnerability in the web user interface of Cisco IOS XE 3.1 through 3.17 could allow an unauthenticated, remote attacker to cause an affected device to reload. The vulnerability is due to insufficient resource handling by the affected software when the web user interface is under a high load. An attacker could exploit this vulnerability by sending a high number of requests to the web user interface of the affected software. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a denial of service (DoS) condition. To exploit this vulnerability, the attacker must have access to the management interface of the affected software, which is typically connected to a restricted management network. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS XE Software, if the web user interface of the software is enabled. By default, the web user interface is not enabled. Cisco Bug IDs: CSCup70353. | |||||
CVE-2017-3820 | 1 Cisco | 1 Ios Xe | 2025-04-20 | 6.8 MEDIUM | 6.5 MEDIUM |
A vulnerability in Simple Network Management Protocol (SNMP) functions of Cisco ASR 1000 Series Aggregation Services Routers running Cisco IOS XE Software Release 3.13.6S, 3.16.2S, or 3.17.1S could allow an authenticated, remote attacker to cause high CPU usage on an affected device, resulting in a denial of service (DoS) condition. More Information: CSCux68796. Known Affected Releases: 15.5(3)S2.1 15.6(1)S1.1. Known Fixed Releases: 15.4(3)S6.1 15.4(3)S6.2 15.5(3)S2.2 15.5(3)S3 15.6(0.22)S0.23 15.6(1)S2 16.2(0.295) 16.3(0.94) 15.5.3S3. | |||||
CVE-2017-3858 | 1 Cisco | 1 Ios Xe | 2025-04-20 | 9.0 HIGH | 8.8 HIGH |
A vulnerability in the web framework of Cisco IOS XE Software could allow an authenticated, remote attacker to inject arbitrary commands that are executed with root privileges. The vulnerability is due to insufficient input validation of HTTP parameters supplied by the user. An attacker could exploit this vulnerability by authenticating to the device and submitting crafted input to the affected web page parameter. The user must be authenticated to access the affected parameter. A successful exploit could allow the attacker to execute commands with root privileges. This vulnerability affects Cisco devices running Cisco IOS XE Software Release 16.2.1, if the HTTP Server feature is enabled for the device. The newly redesigned, web-based administration interface was introduced in the Denali 16.2 Release of Cisco IOS XE Software. The web-based administration interface in earlier releases of Cisco IOS XE Software is not affected by this vulnerability. Cisco Bug IDs: CSCuy83069. | |||||
CVE-2017-3863 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 7.8 HIGH | 8.6 HIGH |
Multiple vulnerabilities in the EnergyWise module of Cisco IOS (12.2 and 15.0 through 15.6) and Cisco IOS XE (3.2 through 3.18) could allow an unauthenticated, remote attacker to cause a buffer overflow condition or a reload of an affected device, leading to a denial of service (DoS) condition. These vulnerabilities are due to improper parsing of crafted EnergyWise packets destined to an affected device. An attacker could exploit these vulnerabilities by sending crafted EnergyWise packets to be processed by an affected device. An exploit could allow the attacker to cause a buffer overflow condition or a reload of the affected device, leading to a DoS condition. Cisco IOS Software and Cisco IOS XE Software support EnergyWise for IPv4 communication. Only IPv4 packets destined to a device configured as an EnergyWise domain member can trigger these vulnerabilities. IPv6 packets cannot be used to trigger these vulnerabilities. Cisco Bug ID CSCut50727. | |||||
CVE-2017-6740 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-20 | 9.0 HIGH | 8.8 HIGH |
The Simple Network Management Protocol (SNMP) subsystem of Cisco IOS 12.0 through 12.4 and 15.0 through 15.6 and IOS XE 2.2 through 3.17 contains multiple vulnerabilities that could allow an authenticated, remote attacker to remotely execute code on an affected system or cause an affected system to reload. An attacker could exploit these vulnerabilities by sending a crafted SNMP packet to an affected system via IPv4 or IPv6. Only traffic directed to an affected system can be used to exploit these vulnerabilities. The vulnerabilities are due to a buffer overflow condition in the SNMP subsystem of the affected software. The vulnerabilities affect all versions of SNMP: Versions 1, 2c, and 3. To exploit these vulnerabilities via SNMP Version 2c or earlier, the attacker must know the SNMP read-only community string for the affected system. To exploit these vulnerabilities via SNMP Version 3, the attacker must have user credentials for the affected system. All devices that have enabled SNMP and have not explicitly excluded the affected MIBs or OIDs should be considered vulnerable. Cisco Bug IDs: CSCve66601. | |||||
CVE-2015-0646 | 1 Cisco | 2 Ios, Ios Xe | 2025-04-12 | 7.8 HIGH | N/A |
Memory leak in the TCP input module in Cisco IOS 12.2, 12.4, 15.0, 15.2, 15.3, and 15.4 and IOS XE 3.3.xXO, 3.5.xE, 3.6.xE, 3.8.xS through 3.10.xS before 3.10.5S, and 3.11.xS and 3.12.xS before 3.12.3S allows remote attackers to cause a denial of service (memory consumption or device reload) by sending crafted TCP packets over (1) IPv4 or (2) IPv6, aka Bug ID CSCum94811. | |||||
CVE-2015-4243 | 1 Cisco | 8 Asr 1001, Asr 1001-x, Asr 1002 and 5 more | 2025-04-12 | 6.1 MEDIUM | N/A |
The PPPoE establishment implementation in Cisco IOS XE 3.5.0S on ASR 1000 devices allows remote attackers to cause a denial of service (device reload) by sending malformed PPPoE Active Discovery Request (PADR) packets on the local network, aka Bug ID CSCty94202. | |||||
CVE-2014-3355 | 1 Cisco | 1 Ios Xe | 2025-04-12 | 7.8 HIGH | N/A |
The metadata flow feature in Cisco IOS 15.1 through 15.3 and IOS XE 3.3.xXO before 3.3.1XO, 3.6.xS and 3.7.xS before 3.7.6S, and 3.8.xS, 3.9.xS, and 3.10.xS before 3.10.1S allows remote attackers to cause a denial of service (device reload) via malformed RSVP packets, aka Bug ID CSCug75942. |