Filtered by vendor Tendacn
Subscribe
Total
106 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-41465 | 1 Tendacn | 2 Fh1201, Fh1201 Firmware | 2024-08-01 | N/A | 7.5 HIGH |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/setcfm. | |||||
CVE-2024-41464 | 1 Tendacn | 2 Fh1201, Fh1201 Firmware | 2024-08-01 | N/A | 7.5 HIGH |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic | |||||
CVE-2024-41463 | 1 Tendacn | 2 Fh1201, Fh1201 Firmware | 2024-08-01 | N/A | 7.5 HIGH |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/addressNat. | |||||
CVE-2024-41462 | 1 Tendacn | 2 Fh1201, Fh1201 Firmware | 2024-08-01 | N/A | 7.5 HIGH |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/DhcpListClient. | |||||
CVE-2024-41461 | 1 Tendacn | 2 Fh1201, Fh1201 Firmware | 2024-08-01 | N/A | 9.8 CRITICAL |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient. | |||||
CVE-2024-41460 | 1 Tendacn | 2 Fh1201, Fh1201 Firmware | 2024-08-01 | N/A | 9.8 CRITICAL |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/RouteStatic. | |||||
CVE-2024-41459 | 1 Tendacn | 2 Fh1201, Fh1201 Firmware | 2024-08-01 | N/A | 9.8 CRITICAL |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex. | |||||
CVE-2024-35338 | 1 Tendacn | 2 I29, I29 Firmware | 2024-08-01 | N/A | 9.8 CRITICAL |
Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root. | |||||
CVE-2024-33182 | 1 Tendacn | 2 Ac18, Ac18 Firmware | 2024-08-01 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter. | |||||
CVE-2024-33180 | 1 Tendacn | 2 Ac18, Ac18 Firmware | 2024-08-01 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo. | |||||
CVE-2024-0932 | 1 Tendacn | 2 Ac10u, Ac10u Firmware | 2024-05-17 | 5.8 MEDIUM | 9.8 CRITICAL |
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0931 | 1 Tendacn | 2 Ac10u, Ac10u Firmware | 2024-05-17 | 5.8 MEDIUM | 9.8 CRITICAL |
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. This vulnerability affects the function saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0930 | 1 Tendacn | 2 Ac10u, Ac10u Firmware | 2024-05-17 | 5.8 MEDIUM | 9.8 CRITICAL |
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0929 | 1 Tendacn | 2 Ac10u, Ac10u Firmware | 2024-05-17 | 5.8 MEDIUM | 9.8 CRITICAL |
A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been rated as critical. Affected by this issue is the function fromNatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-252134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0928 | 1 Tendacn | 2 Ac10u, Ac10u Firmware | 2024-05-17 | 5.8 MEDIUM | 9.8 CRITICAL |
A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-0535 | 1 Tendacn | 2 Pa6, Pa6 Firmware | 2024-05-17 | 9.0 HIGH | 9.8 CRITICAL |
A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Affected by this vulnerability is the function cgiPortMapAdd of the file /portmap of the component httpd. The manipulation of the argument groupName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250705 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-24488 | 1 Tendacn | 2 Cp3, Cp3 Firmware | 2024-02-15 | N/A | 5.5 MEDIUM |
An issue in Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 allows a local attacker to obtain sensitive information via the password component. | |||||
CVE-2022-36552 | 1 Tendacn | 2 Ac6, Ac6 Firmware | 2024-02-14 | N/A | 7.5 HIGH |
Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains an issue in the component /cgi-bin/DownloadFlash which allows attackers to steal all data such as source code and system files via a crafted GET request. | |||||
CVE-2022-37176 | 1 Tendacn | 2 Ac6, Ac6 Firmware | 2024-02-14 | N/A | 9.8 CRITICAL |
Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains a vulnerability which allows attackers to remove the Wi-Fi password and force the device into open security mode via a crafted packet sent to goform/setWizard. | |||||
CVE-2023-37144 | 2 Tenda, Tendacn | 2 Ac10, Ac10 Firmware | 2024-02-04 | N/A | 9.8 CRITICAL |
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. |