Total
61 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-36569 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 8.8 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg. | |||||
CVE-2022-36568 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 8.8 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList. | |||||
CVE-2022-36273 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg. | |||||
CVE-2022-28560 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload | |||||
CVE-2022-27022 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload. | |||||
CVE-2022-27016 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn. | |||||
CVE-2022-26278 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function. | |||||
CVE-2022-25441 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function. | |||||
CVE-2022-25440 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function. | |||||
CVE-2022-25439 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function. | |||||
CVE-2022-25438 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function. | |||||
CVE-2022-25437 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function. | |||||
CVE-2022-25435 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function. | |||||
CVE-2022-25434 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function. | |||||
CVE-2022-25433 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function. | |||||
CVE-2022-25431 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function. | |||||
CVE-2022-25429 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function. | |||||
CVE-2022-25428 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function. | |||||
CVE-2022-25427 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function. | |||||
CVE-2022-25418 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi. |